CONTRAST
Functions
CONTRAST
Set
CONTRAST?
Get
Description
Set contrast value
Set
Get
Get contrast value
Response
~nn@CONTRASTSPstage,channel,valueCR LF
Parameters
stage – 1/IN (input), 2/OUT (output)
channel – input or output number: 1-32 (varies according to installed input / output cards, see
Numbering
on page 14)
value – contrast in Kramer units: 0-63, ++ (increase current value), -- (decrease current value)
Response Trigger
Notes
A minus sign precedes negative values
This command is only valid for VGA cards
K-Config Example
Set the contrast value of output 8 to 60:
"#CONTRAST 2,8,60",0x0D
Increase the contrast value of input 5 by 1 unit:
"#CONTRAST 1,5,++",0x0D
VS-3232DN-EM – Protocol 3000
Permission
End User
End User
Syntax
#CONTRASTSPstage,channel,valueCR