Menus P, Q and R: Option module set-up

Figure 8-38 Location of option module slots and their corresponding menu numbers
1. Solutions Module Slot 1 - Menu P
2. Solutions Module Slot 2 - Menu Q
3. Solutions Module Slot 3 - Menu R
8.15.1
Parameters common to all categories
Parameter
mm01 Module ID
mm02 Software Version
mm03 Hardware Version
mm04 Serial Number LS
mm05 Serial Number MS
The option module ID indicates the type of module that is installed in the corresponding slot. See the relevant option module user guide for more
information regarding the module.
Option module ID
0
209
310
311
304
443
447
448
E300 Design Guide
Issue Number: 1
Electrical
Getting
User Menu A Commissioning
installation
started
Range( )
0 to 65535
00.00.00 to 99.99.99
0.00 to 99.99
0 to 99999999
Module
No module installed
SI-I/O
MCi 210
MCi 200
SI-Applications Plus
SI-PROFIBUS
SI-DeviceNet
SI-CANopen
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Default( )
Automation (I/O Expansion)
Automation (Applications)
Type
RO Num ND NC PT
RO Num ND NC PT
RO Num ND NC PT
RO Num ND NC PT
RO Num ND NC PT
Category
Fieldbus