Emerson E300 Series Design Manual page 364

Advanced elevator drive / dedicated elevator variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for E300 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
J82
Day Of Week
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Default
Type
8 Bit Volatile
Display Format
Date
Coding
RO, TE, ND, NC, PT
Value
0
1
2
3
4
5
6
See Date (J80).
J83
Date And Time Offset
Mode
Open-Loop, RFC-A, RFC-S
Minimum
-24.00
Default
0.00
Type
16 Bit User Save
Display Format
Standard
Coding
RW
Date And Time Offset (J83) is an offset, specified in hours, that can be applied to the Time (J81). If the offset applied causes the time to roll-over
midnight then the Date (J80) and Day Of Week (J82) are also modified. The offset is only applied when the clock source is a clock derived from a
keypad or option module, i.e. Date/Time Selector (H32) > 3. The offset can be used for time zone offsets or daylight saving time etc. It should be
noted that when the date and time is derived from an option module this may be in the form of UTC (Co-ordinated Universal Time) with an additional
offset also provided by the option module. The data and time is derived by adding the additional offset and the time from the option module and then
adding Date And Time Offset (J83).
J84
Energy Meter: MWh
Mode
Open-Loop, RFC-A, RFC-S
Minimum
-999.9
Default
Type
16 Bit Power Down Save
Display Format
Standard
Coding
RO, ND, NC, PT
See Reset Energy Meter (H37).
J85
Energy Meter: kWh
Mode
Open-Loop, RFC-A, RFC-S
Minimum
-99.99
Default
Type
16 Bit Power Down Save
Display Format
Standard
Coding
RO, ND, NC, PT
See Reset Energy Meter (H37).
364
Electrical
Getting
User Menu A Commissioning
installation
started
Text
Sunday
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Maximum
6
Units
Update Rate
Background write
Decimal Places
0
Maximum
24.00
Units
Hours
Update Rate
Background read
Decimal Places
2
Maximum
999.9
Units
MWh
Update Rate
Background write
Decimal Places
1
Maximum
99.99
Units
kWh
Update Rate
Background write
Decimal Places
2