Emerson E300 Series Design Manual page 318

Advanced elevator drive / dedicated elevator variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for E300 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
H32
Date/Time Selector
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Default
1
Type
8 Bit User Save
Display Format
Standard
Coding
RW, TE
Value
0
1
2
3
4
5
6
7
8
9
Date/Time Selector (H32) is used to select the drive date and time as shown in the table below.
Date/Time
Selector (H32)
0: Set
Date and time parameters can be written by the user.
1: Power
Time since the drive was powered up.
2: Running
Accumulated drive running time since the drive was manufactured.
3: Acc Power
Accumulated powered-up time since the drive was manufactured.
If a keypad fitted to the front of the drive includes a real-time clock then the date/time from this clock is displayed, otherwise
4: Local Keypad
the date/time is set to zero.
If a keypad connected to the user comms port of a drive with a 485 includes a real-time clock then the date/time from this clock
5: Remote Keypad
is displayed, otherwise the date/time is set to zero.
6: Slot 1
As 4 above, but for option slot 1
7: Slot 2
As 4 above, but for option slot 2
8: Slot 3
As 4 above, but for option slot 3
9: Slot 4
As 4 above, but for option slot 4
When Date/Time Selector (H32) = 0 the Date (J80) and Time (J81) can be written by the user and the values in these parameters are transferred to
the real time clocks in the keypad or any option modules that support this feature that are fitted to the drive. When Date/Time Selector (H32) is
changed to any other value, the real time clocks are allowed to run normally again. When Date/Time Selector (H32) is changed from any value to 0
the date and time from a real time clock, if present, is automatically loaded into Date (J80) and Time (J81), so that this date and time is used as the
initial value for editing. If more than one real time clock is present the date/time from the keypad is used, if present, and if not then the date/time from
the lowest number slot with a real time clock is used.
Date (J80) and Time (J81) are used for time stamping trips. These features will continue to use the originally selected clock even if Date/Time
Selector (H32) is changed until a drive reset is initiated. If Date/Time Selector (H32) has been changed and a reset is initiated, the trip dates and
times (L41 to L60) are reset to zero.
H33
Date Format
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Default
0
Type
8 Bit User Save
Display Format
Standard
Coding
RW, TE
Value
0
1
318
Electrical
Getting
User Menu A Commissioning
installation
started
Text
Set
Powered
Running
Acc Powered
Local Keypad
Remote Keypad
Slot 1
Slot 2
Slot 3
Slot 4
Text
Standard
US
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Maximum
9
Units
Update Rate
Background read
Decimal Places
0
Date/Time Source
Maximum
1
Units
Update Rate
Background read
Decimal Places
0
E300 Design Guide