No travel interrupt
1
Travel interrupt during while waiting for the enable input in state 1, Elevator Software State (J03) = 1.
2
Travel interrupt during the motor contactor de-bounce time in state 2, Elevator Software State (J03) = 2.
3
Travel interrupt during ramping the drive torque / brake release logic in state3 Elevator Software State (J03) = 3.
4
Travel interrupt during the brake release delay in state 4, Elevator Software State (J03) = 4.
5
Travel interrupt during the load measurement delay in state 5, Elevator Software State (J03) = 5.
6
Travel interrupt during start optimization in state 6, Elevator Software State (J03) = 6.
7
Travel interrupt during acceleration in state 7, Elevator Software State (J03) = 7.
8
Travel interrupt during travelling in state 8, Elevator Software State (J03) = 8.
9
Travel interrupt during deceleration in state 9, Elevator Software State (J03) = 9.
10
Travel interrupt during creep state 10, Elevator Software State (J03) = 10.
11
Travel interrupt during positioning in state 11, Elevator Software State (J03) = 11.
12
Travel interrupt during brake apply delay in state 12, Elevator Software State (J03) = 12.
13
Travel interrupt during torque ramp / brake apply in state 13, Elevator Software State (J03) = 13.
L04
Mode
Minimum
Default
Type
Display Format
Coding
When set to On (1), indicates that an error has been detected during travel. The trip for the given error will only happen when the elevator has finished
the current travel.
The following trips are suppressed during a travel:
Motor thermistor Trip 24 (Thermistor)
Brake monitoring Trip 72 (Brk con 1 open), Trip 73 (Brk con 1 closd), Trip 74 (Brk con 2 open) and Trip 75 (Brk con 2 closd)
Motor contactor monitoring Trip 70 (Mot con open) and Trip 71 (Mot con closd)
Heat sink over temperature Trip 22 (OHt Power), the trip will happen when the next travel is initiated.
The direction signal monitoring Trip 76 (Dir change)
Control word watchdog bit monitoring, Trip 77 (Ctrl Watchdog).
The freeze protection monitoring, trip 60 (Freeze protect).
L05
Mode
Minimum
Default
Type
Display Format
Coding
Drive OK (L05) indicates that the drive is not in the trip or the under voltage state if it is set to one.
Drive State
Normal power and Drive OK (L05) = 1
Normal power and Drive OK (L05) = 0
Standby power state
E300 Design Guide
Issue Number: 1
Electrical
Getting
User Menu A Commissioning
installation
started
Global Warning
Open-Loop, RFC-A, RFC-S
0
1 Bit Volatile
Standard
RO, ND, NC, PT
Drive OK
Open-Loop, RFC-A, RFC-S
0
1 Bit Volatile
Standard
RO, ND, NC, PT
LED
On continuously
Flashing: 0.5 s on and 0.5 s off
Flashing: 0.5 s on and 7.5 s off
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Description
Maximum
1
Units
Update Rate
Background write
Decimal Places
0
Maximum
1
Units
Update Rate
Background write
Decimal Places
0
389

Advertisement

Table of Contents
loading

Table of Contents