Emerson E300 Series Design Manual page 268

Advanced elevator drive / dedicated elevator variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for E300 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Mode: Open-Loop, RFC-A, RFC-S
F01
IO Status Word
Mode
Open-Loop, RFC-A, RFC-S
0
Minimum
(Display: 0000000000000000)
Default
Type
16 Bit Volatile
Display Format
Binary
Coding
RO, PT, BU
The bits in the IO Status Word (F01) each correspond with one digital I/O as shown below. The update rate of the individual bits in these registers
differs depending upon the I/O.
DI/O
Bit
1
0
Digital Input/Output
2
1
Digital Input/Output
3
2
Digital Input/Output
4
3
Digital Input
5
4
Digital Input
6
5
Digital Input
7
6
Relay Output
8
7
24 V Supply Output
9
8
Safe Torque Off 1
10
9
Safe Torque Off 2
11
10
Keypad Run Button
12
11
Keypad Auxiliary Button
13
12
24 V Supply Input
14
13
Keypad Stop Button
15
14
Relay 2 Output
The IO Status Word (F01) is always active and shows the value in the Digital I/O State parameter for all digital I/O configured as inputs.
F02
Input Logic Polarity
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Default
1
Type
8 Bit User Save
Display Format
Standard
Coding
RW, TE, BU
Value
0
1
See T24 Digital I/O 01 State (F03).
F03
T24 Digital I/O 01 State
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Default
Type
1 Bit Volatile
Display Format
Standard
Coding
RO, ND, NC, PT
The Digital I/O State parameter shows the state of digital I/O on the drive. All I/O except Digital Input 11 (Keypad Run Button), Digital Input 12 (Keypad
Auxiliary Button), Digital Input 13 (24 V Supply Input) and Digital Input 14 (Keypad Stop Button) use IEC61131-2 logic levels. As default the inputs use
positive logic, and so the state parameter is 0 if the digital I/O is low or 1 if the digital I/O is high. Input Logic Polarity (F02) can be set to zero to change
268
Electrical
Getting
User Menu A Commissioning
installation
started
Function
Input Register
2 ms
2 ms
2 ms
250 μs
250 μs
2 ms
Bit always 0
Bit always 0
2 ms
2 ms
Background
Background
2 ms
Background
Bit always 0
Text
Negative Logic
Positive Logic
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
65535
Maximum
(Display: 1111111111111111)
Units
Update Rate
250 µs write
Decimal Places
0
Bit update rate
Output Register
250 µs
250 µs
2 ms
Not applicable
Not applicable
Not applicable
2 ms
2 ms
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
2 ms
Maximum
1
Units
Update Rate
Background read
Decimal Places
0
Maximum
1
Units
Update Rate
2 ms write
Decimal Places
0
Output Enable Register
Background
Background
Background
Not applicable
Not applicable
Not applicable
Background
Background
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Not applicable
Background
E300 Design Guide
Issue Number: 1