Coding
When V5 is the creep speed in creep to floor mode:
When Creep Speed Select (G52) = V5 (5) this shows the distance from V5 Speed Reference (G05) to a stop in mm. The distance is calculated from
V5 Speed Reference (G05), Creep Stop Deceleration Rate (G17), and Creep Stop Jerk (G18).
When V5 is not the creep speed in creep to floor mode:
This indicates the distance from V5 Speed Reference (G05) to the creep speed defined by Creep Speed Select (G52) in mm. The distance is
calculated from V5 Speed Reference (G05), the creep speed defined by Creep Speed Select (G52), Deceleration Rate (G12), Run Jerk 3 (G15) and
Run Jerk 4 (G16).
Direct to floor:
In Direct to floor, Elevator Control Mode (H19) = Direct To Floor (1), this indicates the distance from V5 Speed Reference (G05) to a stop in mm. The
distance is calculated from V5 Speed Reference (G05), Deceleration Rate (G12), Run Jerk 3 (G15) and Run Jerk 4 (G16).
J15
Mode
Minimum
Default
Type
Display Format
Coding
When V6 is the creep speed in creep to floor mode:
When Creep Speed Select (G52) = V6 (6) this shows the distance from V6 Speed Reference (G06) to a stop in mm. The distance is calculated from
V6 Speed Reference (G06), Creep Stop Deceleration Rate (G17), and Creep Stop Jerk (G18).
When V6 is not the creep speed in creep to floor mode:
This indicates the distance from V6 Speed Reference (G06) to the creep speed defined by Creep Speed Select (G52) in mm. The distance is
calculated from V6 Speed Reference (G06), the creep speed defined by Creep Speed Select (G52), Deceleration Rate (G12), Run Jerk 3 (G15) and
Run Jerk 4 (G16).
Direct to floor:
In Direct to floor, Elevator Control Mode (H19) = Direct To Floor (1), this indicates the distance from V6 Speed Reference (G06) to a stop in mm. The
distance is calculated from V6 Speed Reference (G06), Deceleration Rate (G12), Run Jerk 3 (G15) and Run Jerk 4 (G16).
J16
Mode
Minimum
Default
Type
Display Format
Coding
When V7 is the creep speed in creep to floor mode:
When Creep Speed Select (G52) = V7 (7) this shows the distance from V7 Speed Reference (G07) to a stop in mm. The distance is calculated from
V7 Speed Reference (G07), Creep Stop Deceleration Rate (G17), and Creep Stop Jerk (G18).
When V7 is not the creep speed in creep to floor mode:
This indicates the distance from V7 Speed Reference (G07) to the creep speed defined by Creep Speed Select (G52) in mm. The distance is
calculated from V7 Speed Reference (G07), the creep speed defined by Creep Speed Select (G52), Deceleration Rate (G12), Run Jerk 3 (G15) and
Run Jerk 4 (G16).
Direct to floor:
In Direct to floor, Elevator Control Mode (H19) = Direct To Floor (1), this indicates the distance from V7 Speed Reference (G07) to a stop in mm. The
distance is calculated from V Speed Reference (G07), Deceleration Rate (G12), Run Jerk 3 (G15) and Run Jerk 4 (G16).
E300 Design Guide
Issue Number: 1
Electrical
Getting
User Menu A Commissioning
installation
started
V5 Calculated Deceleration Distance
Open-Loop, RFC-A, RFC-S
0
16 Bit Volatile
Standard
RO, ND, NC, PT
V6 Calculated Deceleration Distance
Open-Loop, RFC-A, RFC-S
0
16 Bit Volatile
Standard
RO, ND, NC, PT
V7 Calculated Deceleration Distance
Open-Loop, RFC-A, RFC-S
0
16 Bit Volatile
Standard
RO, ND, NC, PT
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Maximum
10000
Units
Update Rate
Background
Decimal Places
0
Maximum
10000
Units
Update Rate
Background
Decimal Places
0
Maximum
10000
Units
Update Rate
Background
Decimal Places
0
343