Ratings - Emerson E300 Series Design Manual

Advanced elevator drive / dedicated elevator variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for E300 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
2.4

Ratings

The E300 Advanced Elevator drive is configured for Heavy Duty operation, For constant torque applications or applications which require a high
overload capability, or full torque is required at low speeds (e.g. elevators, hoists). The thermal protection is set to protect force ventilated induction
motors and permanent magnet servo motors by default.
2
Motor I
t protection defaults to be compatible with:
N
NOTE
If the application uses a self ventilated (TENV/TEFC) induction motor and increased thermal protection is required for speeds below 50 % base
speed, then this can be enabled by setting Low Speed Thermal Protection Mode (B44) = On (1).
The rating label details the available output current under the following conditions:
40 °C (104 °F) maximum ambient,
1000 m altitude,
8 kHz switching frequency,
A typical elevator profile (50 % ED),
IGBT lifetime optimization enabled (reduction of switching frequency based on drive inverter temperature).
Derating is required for higher switching frequencies, ambient temperatures >40 °C (104 °F) and higher altitude. For derating information, refer to
section 2.4.2 Power and current ratings (derating for switching frequency and temperature) on page 14.
The input current is affected by the supply voltage and impedance. The input current given on the rating label is the typical input current and is stated
for a balanced supply.
Fuses
The AC supply to the drive must be installed with suitable protection against overload and short-circuits. The following section shows
recommended fuse ratings. Failure to observe this requirement will cause risk of fire.
WARNING
Table 2-1 200 V drive and AC fuse ratings
Max. cont.
input current
Model
3 ph
A
03200106
20
04200137
20
04200185
28
05200250
31
06200330
48
06200440
56
07200610
67
07200750
84
07200830
105
Table 2-2 400 V drive and AC fuse ratings
Max. cont.
input current
Model
3ph
A
03400062
13
03400078
13
03400100
16
04400150
19
04400172
24
05400270
29
05400300
30
06400350
36
06400420
46
06400470
60
07400660
74
07400770
88
07401000
105
* These fuses are fast acting.
12
Electrical
Getting
User Menu A Commissioning
installation
started
Heavy Duty
Nom power
Max. cont.
@
output current
230 V
A
kW
10.6
2.2
13.7
3
18.5
4
25
5.5
33
7.5
44
11
61
15
75
18.5
83
22
Heavy Duty
Nom power
Max. cont.
@
output current
400 V
A
kW
6.2
2.2
7.8
3
10
4
15
5.5
17.2
7.5
27
11
30
15
35
15
42
18.5
47
22
66
30
77
37
100
45
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Motor power
IEC
@
Nom
230 V
hp
A
3
25
3
25
5
32
7.5
40
10
63
15
63
20
80
25
100
30
125
Motor power
IEC
@
Nom
460 V
hp
A
3.0
20
5.0
20
5.0
20
10.0
25
10.0
32
40
20
40
25
63
30
63
30
63
50
100
60
100
75
125
Fuse
UL
Nom
Class
Class
A
gG
25
CC, J or T*
25
gG
CC, J or T*
30
gG
40
CC, J or T*
60
gG
CC, J or T*
70
80
gG
100
CC, J or T*
125
Fuse
UL
Nom
Class
Class
A
20
gG
20
CC, J or T*
20
25
gG
CC, J or T*
30
35
gG
CC, J or T*
35
40
gR
50
HSJ or DFJ
70
80
gG
100
CC, J or T*
125
E300 Design Guide
Issue Number: 1

Advertisement

Table of Contents
loading

Table of Contents