Shield, Ground connections

Shielding considerations are important for PWM drive installations due to the high voltages and currents present in the output (motor) circuit with a
very wide frequency spectrum, typically from 0 to 20 MHz.
Resolver connections:
Use a cable with an overall shield and twisted pairs for the resolver signals
Connect the cable shield to the drive 0 V connection by the shortest possible link ("pigtail")
It is generally preferable not to connect the cable shield to the resolver. However in cases where there is an exceptional level of common-mode
noise voltage present on the resolver body, it may be helpful to connect the shield there. In this case ensure absolute minimum lengths of
"pigtails" are used at both shield connections. Also clamp the cable shield directly to the resolver body and the drive grounding bracket
Preferably the cable should not be interrupted. Where interruption is unavoidable, ensure minimal length of "pigtail" shield connections at each
interruption.
Encoder connections:
Use a cable with the correct impedance
Use a cable with individually shielded twisted pairs
Connect the cable shields to 0V at both the drive and the encoder, using the shortest possible links ("pigtails")
Preferably the cable should not be interrupted. If interrupted, ensure the absolute minimum length of "pigtail" in the shield connections at each
interruption. Preferably, use a connection method which provides substantial metallic clamps for the cable shield terminations
The above applies where the encoder body is isolated from the motor and where the encoder circuit is isolated from the encoder body. Where there is
no isolation between the encoder circuits and the motor body, and if in any doubt, the following additional requirement must be observed in the
interests of best possible noise immunity.
The shields must be directly clamped to the encoder body (no pigtail) and to the drive grounding bracket. This may be achieved by clamping of
the individual shields or by providing an additional overall shield which is clamped
N
NOTE
The recommendations of the encoder manufacturer must also be adhered to for the encoder connections.
Motor cable: Use a motor cable with an overall shield. Connect the shield of the motor cable to the ground terminal of the motor frame using a link
that is as short as possible and not exceeding 50 mm (2 in) long. A full 360 ° termination of the shield to the terminal housing of the motor is beneficial.
Brake resistor cable: The optional braking resistor should also be wired with shielded cable. If un-shielded wire is required refer to section
4.17.5 Shielding requirements for the braking circuit on page 102 for guidance.
Control cables (including encoder): If the control wiring is to leave the enclosure, it must be shielded and the shield(s) clamped to the drive using
the grounding bracket. Remove the outer insulating cover of the cable to ensure the shield(s) make contact with the bracket but keep the shield(s)
intact until as close as possible to the terminals. Refer to Figure 4-36 Grounding of signal cable shields using the grounding bracket on page 102.
Figure 4-14 Feedback cable, twisted pair and Figure 4-15 Feedback cable connections illustrate the preferred construction of cable and the method
of clamping.
Figure 4-14 Feedback cable, twisted pair
N
NOTE
In order to guarantee maximum noise immunity for any application double shielded cable as shown should be used.
Figure 4-15 Feedback cable connections
Connection
at drive
Use the grounding bracket and grounding clamp supplied with the drive to terminate all shielded cables at the drive.
E300 Design Guide
Issue Number: 1
Electrical
Getting
User Menu A Commissioning
installation
started
Twisted
pair
cable
Twisted
pair
Shield
shield
connection
to 0V
Cable
shield
Advanced
Parameters
Cable overall shield
Cable
Twisted pair shield
Twisted
pair
shield
Cable
Cable
Ground clamp
shield
on shield
Diagnostics Optimization CT MODBUS RTU Technical Data
Shield
connection
to 0V
Connection
at motor
79