installation
The table below details the bits within the control word and their function:
Bit
Selects V1 Speed Reference (Creep speed by default). If a higher priority speed is selected it will override this speed
0
selection.
1
Selects V2 Speed Reference. If a higher priority speed is selected it will override this speed selection.
2
Selects V3 Speed Reference. If a higher priority speed is selected it will override this speed selection.
3
Selects V4 Speed Reference. If a higher priority speed is selected it will override this speed selection.
4
Selects V5 Speed Reference. If a higher priority speed is selected it will override this speed selection.
5
Selects V6 Speed Reference. If a higher priority speed is selected it will override this speed selection.
6
Selects V7 Speed Reference. If a higher priority speed is selected it will override this speed selection.
7
Selects V8 Speed Reference. If a higher priority speed is selected it will override this speed selection.
8
Selects V9 Speed Reference. If a higher priority speed is selected it will override this speed selection.
9
Selects V10 Speed Reference. If a higher priority speed is selected it will override this speed selection.
10
Direction input 1 CCW
11
Direction input 2 CW
Watchdog bit. This must be set to 1 at least every 500 ms. Failure to do this will result in a Trip 77 (Ctrl Watchdog). If a
12
travel is in progress the elevator will perform a controlled stop and then trip.
13
Reserved
14
Reserved
15
Reserved
A11 {H12}
Direction Input Invert
RW
Bit
OL
RFC-A
Off (0) or On (1)
RFC-S
A11 (Direction Input Invert H12)
When set to Off (0) the direction input operation is not inverted. For single direction input operation, if Direction Input 1 (CCW G39) = Off (0) clockwise
direction is selected, and if Direction Input 1 (CCW G39) = On (1) then counter clockwise direction is selected. For dual direction input operation, if
Direction Input 1 (CCW G39) = On (1) then counter clockwise direction is selected, and if Direction Input 2 CW (G40) = On (1) then clockwise
direction is selected.
When set to On (1), the direction input operation is inverted. For single direction input operation, if Direction Input 1 CCW (G39) = Off (0) counter
clockwise direction is selected, and if Direction Input 1 CCW (G39) = On (1) then clockwise direction is selected. For dual direction input operation, if
Direction Input 1 (CCW G39) = On (1) then clockwise direction is selected, and if Direction Input 2 (CW G40) = On (1) then counter clockwise
direction is selected. Parameter A10 (Control Input Mode H09) selects either single or dual direction input mode.
A12 {C01}
Drive Encoder Type
RW
Txt
OL
RFC-A
AB (0), FD (1), FR (2),
AB Servo (3), FD Servo (4),
FR Servo (5), SC (6),
SC Hiperface (7), EnDat (8),
SC EnDat (9), SSI (10),
RFC-S
SC SSI (11), SC Servo (12),
BiSS (13), SC SC (15),
Commutation Only (16)
A12 (Drive Encoder Type C01)
Encoder type should be set-up based on the position feedback device connected to the drive position feedback interface.
Table 6-5 overleaf details the position feedback types supported.
E300 Design Guide
Issue Number: 1
Electrical
Getting
User Menu
installation
started
A
Description
US
Off (0)
US
AB (0)
AB Servo (3)
Advanced
Commissioning
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Priority
10 (lowest)
9
8
7
6
5
4
3
2
1 (highest)
N/A
N/A
N/A
N/A
N/A
N/A