Safety
Product
Mechanical
information
information
installation
4.6.3
Position feedback terminal specifications
A,F, Cosref, Data, Cos H
1
A\,F\ Cosref\, Data\, Cos L
2
AB (0), FD (1), FR (2), AB Servo (3), FD Servo (4), FR Servo (5)
Type
Line termination components
Working common mode range
SC Hiperface (7), SC EnDat (9), SC SSI (11), SC Servo (12), SC SC (15)
Type
Maximum Signal level
Maximum applied differential voltage and common mode voltage range
EnDat (8), SSI (10), BISS (13)
Type
Line termination components
Working common mode range
Common to All
Absolute maximum applied voltage relative to 0V
B, D, R Sinref, Clock, Sin H
3
B\, D\, R\, Sinref\, Clock\, Sin L
4
AB (0), FD (1), FR 2), AB Servo (3), FD Servo (4), FR Servo (5
Type
Line termination components
Working common mode range
SC Hiperface (7), SC EnDat (9), SC SSI (11), SC Servo (12), SC SC (15)
Type
Maximum Signal level
Maximum applied differential voltage and common mode voltage range
EnDat (8), SSI (10), BISS (13)
Type
Line termination components
Working common mode range
Common to All
Absolute maximum applied voltage relative to 0V
76
Electrical
Getting
User Menu A Commissioning
installation
started
)
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
EIA 485 differential receivers
120 Ω (selectable)
– 7 V to + 12 V
Differential voltage
1.25 V peak to peak (sin with regard to sinref and cos with regard
to cosref)
± 4 V
EIA 485 differential receivers
120 Ω (selectable)
– 7 V to + 12 V
- 9 V to + 14 V
EIA 485 differential receivers
120 Ω (selectable)
– 7 V to + 12 V
Differential voltage
1.25 V peak to peak (sin with regard to sinref and cos with regard
to cosref)
± 4 V
EIA 485 differential receivers
120 Ω (selectable)
– 7 V to + 12 V
- 9 V to + 14 V
E300 Design Guide
Issue Number: 1