Emerson E300 Series Design Manual page 295

Advanced elevator drive / dedicated elevator variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for E300 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
G29
Mode
Minimum
Default
Type
Display Format
Coding
This is the fast stop deceleration rate, and is set in mm / s
(1), and is activated via a digital input or comms from the elevator controller.
G30
Mode
Minimum
Default
Type
Display Format
Coding
This sets the short floor landing distance in mm. This is the distance from the current floor to next the floor level. It is intended for situations where the
distance to the next floor is shorter than normal e.g.0.7 m.
When this feature is used the entire profile will be completed as a position controlled profile. For this reason Start optimization is not available when
using this mode.
This parameter is used when Short Floor Landing Enable (H22) = On (1).
G31
Mode
Minimum
Default
Type
Display Format
Coding
This sets the floor sensor correction target distance in mm. This is the distance from the sensor / limit switch to the floor level. It is assumed that the
distance is symmetrical above and below the floor level.
This parameter is used when Floor Sensor Correction Enable (H23) = On (1).
The remaining distance to floor is shown in Remaining Floor Sensor Correction Distance (J47).
G32
Mode
Minimum
Default
Type
Display Format
Coding
This input bit is used to select the bit zero speed input when binary or priority speed selection is used, Control Input mode (H11) = Priority 1 Dir, Binary
1 Dir, Priority 2 Dir or Binary 2 Dir (2, 3, 4 or 5).
In priority input mode this selects V1 Speed Reference (G01), but in binary input mode it may be used to select a number of speeds from V1 to V10.
E300 Design Guide
Issue Number: 1
Electrical
Getting
User Menu A Commissioning
installation
started
Fast Stop Deceleration Rate
Open-Loop, RFC-A, RFC-S
0
500
16 Bit User Save
Standard
RW
2
. This is activated when Fast Stop Enable (H26) or Rapid Slow Down Enable (H27) = On
Short Floor Landing Distance
RFC-A, RFC-S
0
0
16 Bit User Save
Standard
RW, Num, US
Floor Sensor Correction Target Distance
RFC-A, RFC-S
0
0
16 Bit User Save
Standard
RW, Num, US
Reference Select Bit 0 Input
Open-Loop, RFC-A, RFC-S
0
0
1 Bit User Save
Standard
RW
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Maximum
10000
Units
mm / s²
Update Rate
Background
Decimal Places
0
Maximum
10000
Units
mm
Update Rate
Background
Decimal Places
0
Maximum
10000
Units
mm
Update Rate
Background
Decimal Places
0
Maximum
1
Units
Update Rate
4 ms
Decimal Places
0
295