Safety
Product
Mechanical
information
information
installation
G24
Mode
Minimum
Default
Type
Display Format
Coding
This sets the Direct to floor deceleration distance setpoint in mm for V6 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
G25
Mode
Minimum
Default
Type
Display Format
Coding
This sets the Direct to floor deceleration distance setpoint in mm for V7 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
G26
Mode
Minimum
Default
Type
Display Format
Coding
This sets the Direct to floor deceleration distance setpoint in mm for V8 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
G27
Mode
Minimum
Default
Type
Display Format
Coding
This sets the Direct to floor deceleration distance setpoint in mm for V9 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
G28
Mode
Minimum
Default
Type
Display Format
Coding
This sets the Direct to floor deceleration distance setpoint in mm for V10 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
294
Electrical
Getting
User Menu A Commissioning
installation
started
V6 Deceleration Distance Setpoint
RFC-A, RFC-S
0
0
16 Bit User Save
Standard
RW, Num, US
V7 Deceleration Distance Setpoint
RFC-A, RFC-S
0
0
16 Bit User Save
Standard
RW, Num, US
V8 Deceleration Distance Setpoint
RFC-A, RFC-S
0
0
16 Bit User Save
Standard
RW, Num, US
V9 Deceleration Distance Setpoint
RFC-A, RFC-S
0
0
16 Bit User Save
Standard
RW, Num, US
V10 Deceleration Distance Setpoint
RFC-A, RFC-S
0
0
16 Bit User Save
Standard
RW, Num, US
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Maximum
10000
Units
mm
Update Rate
Background
Decimal Places
0
Maximum
10000
Units
mm
Update Rate
Background
Decimal Places
0
Maximum
10000
Units
mm
Update Rate
Background
Decimal Places
0
Maximum
10000
Units
mm
Update Rate
Background
Decimal Places
0
Maximum
10000
Units
mm
Update Rate
Background
Decimal Places
0
E300 Design Guide
Issue Number: 1