Emerson E300 Series Design Manual page 424

Advanced elevator drive / dedicated elevator variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for E300 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
O14
Low Under Voltage Threshold
Mode
Open-Loop, RFC-A, RFC-S
Minimum
-VM_LOW_UNDER_VOLTS
Default
See exceptions below
Type
16 Bit User Save
Display Format
Standard
Coding
RW, VM, RA
Voltage
200V
400V
575V
690V
See Standard Under Voltage Threshold (O11).
O15
Under Voltage Contactor Close Output
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Default
Type
1 Bit Volatile
Display Format
Standard
Coding
RO, ND, NC, PT
See Standard Under Voltage Threshold (O11).
O16
Under Voltage System Contactor Closed
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Default
0
Type
1 Bit Volatile
Display Format
Standard
Coding
RW
See Standard Under Voltage Threshold (O11).
O17
Slow Rectifier Charge Rate Enable
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Default
0
Type
1 Bit User Save
Display Format
Standard
Coding
RW
For frame size 07 drives and larger, which use a d.c. link charge system based on a half controlled thyristor input bridge, the rate at which the d.c. bus
is charged can be reduced by setting Slow Rectifier Charge Rate Enable (O17) to one. This will reduce the charging current which may be required if
significant additional capacitance is added to the d.c. link to prevent rupturing of input fuses.
424
Electrical
Getting
User Menu A Commissioning
installation
started
Default Value
175
330
435
435
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Maximum
VM_LOW_UNDER_VOLTS
Units
V
Update Rate
Background read
Decimal Places
0
Maximum
1
Units
Update Rate
4 ms write
Decimal Places
0
Maximum
1
Units
Update Rate
4 ms read
Decimal Places
0
Maximum
1
Units
Update Rate
Background read
Decimal Places
0
E300 Design Guide
Issue Number: 1