Threshold Detector 1 Output Invert
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Default
0
Type
1 Bit User Save
Display Format
Standard
Coding
RW
See Threshold Detector 1 Output (K23).
K28
Threshold Detector 1 Destination
Mode
Open-Loop, RFC-A, RFC-S
Minimum
A00
Default
A00
Type
16 Bit User Save
Display Format
Menu Param Alpha Numeric
Coding
RW, DE, PT, BU
See Threshold Detector 1 Output (K23).
K29
Variable Selector 1 Output
Mode
Open-Loop, RFC-A, RFC-S
Minimum
-100.00
Default
Type
16 Bit Volatile
Display Format
Standard
Coding
RO, ND, NC, PT
See Variable Selector 1 Source 1 (K30).
K30
Variable Selector 1 Source 1
Mode
Open-Loop, RFC-A, RFC-S
Minimum
A00
Default
A00
Type
16 Bit User Save
Display Format
Menu Param Alpha Numeric
Coding
RW, PT, BU
The variable selector functions are always active even if the source and destination are not routed to valid parameters. If a source is not a valid
parameter then the source value is taken as 0. The update rate for each of the variable selector functions is always 4 ms.
The following description is for variable selector 1, but variable selector 2 operates in the same way. The source parameters selected with Variable
Selector 1 Source 1 (K30) and Variable Selector 1 Source 2 (K31) are converted to a percentage value, scaled with Variable Selector 1 Source 1
Scaling (K34) and Variable Selector 1 Source 2 Scaling (K35) respectively and then combined with a function defined by Variable Selector 1 Mode
(K32) to give Variable Selector 1 Output (K29) as a percentage value. If Variable Selector 1 Enable (K37) = 1 then the function operates normally. If
Variable Selector 1 Enable (K37) = 0 then Variable Selector 1 Output (K29) = 0.00% and any states within the function are reset (i.e. the time
constant function accumulator is held at zero). If the value of Variable Selector 1 Mode (K32) is changed then all internal function state are also reset.
378
Electrical
Getting
User Menu A Commissioning
installation
started
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Maximum
1
Units
Update Rate
4 ms read
Decimal Places
0
Maximum
AB99
Units
Update Rate
Drive reset read
Decimal Places
3
Maximum
100.00
Units
%
Update Rate
4 ms read
Decimal Places
2
Maximum
AB99
Units
Update Rate
Drive reset read
Decimal Places
3
E300 Design Guide