Emerson E300 Series Design Manual page 213

Advanced elevator drive / dedicated elevator variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for E300 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
B30
Mode
Minimum
Default
Type
Display Format
Coding
When Motor Contactor Monitoring Enable (B29) = On (1), then this parameter is used to monitor the state of the motor contactors. One of the elevator
drive inputs or I/O option inputs must be routed to this parameter, where the signal to activate the input comes from the motor contactors auxiliary
contacts.
When set to Off (0), the motor contactors are open, when set to On (1) the motor contactors are closed.
This input is used to generate Trip 70 (Mot con open) / Trip 71 (Mot con closd).
B31
Mode
Minimum
Default
Type
Display Format
Coding
If the motor contactors are to be connected to the elevator drive, route this parameter to a drive digital output, which will control the motor contactors.
When set to Off (0), the motor contactors will be opened.
When set to On (1), the motor contactors will be closed.
A volatile source parameter must be used to prevent the user from saving to On (1).
B32
Mode
Minimum
Default
Type
Display Format
Coding
This indicates the measured contactor opening time delay in ms.
This is the time from when the brake apply delay starts to when the enable is removed – Brake Control Apply Delay (D05) – Motor Torque Ramp Time
(D02). See the following diagram:
A negative time indicates that the contactor opened while current was flowing i.e. drive is disabled (via the motor contactors auxiliary contacts) during
the Brake Control Apply Delay (D05) or the Motor Torque Ramp Time (D02). Negative values can only occur in situations where the Motor contactor
E300 Design Guide
Issue Number: 1
Electrical
Getting
User Menu A Commissioning
installation
started
Motor Contactor Monitoring Input
Open-loop: RFC-A, RFC-S
0
0
1 Bit User Save
Standard
RW
Motor Contactor Control Output
Open-loop: RFC-A, RFC-S
0
0
1 Bit Volatile
Standard
RW
Motor Contactor Measured Delay Time
Open-loop: RFC-A, RFC-S
0
0
16 Bit Volatile
Standard
RO
D05
D02
Motor contactor timing ends
Advanced
Parameters
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
Maximum
Units
Update Rate
Decimal Places
Profile completed here &
Motor contactor timing begins &
Brake contactor control output = 0
B32
Drive disabled &
Diagnostics Optimization CT MODBUS RTU Technical Data
1
4 ms
0
1
4 ms
0
32767
ms
Background
0
Time
213