Emerson E300 Series Design Manual page 334

Advanced elevator drive / dedicated elevator variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for E300 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Parameter
J53
Drive Encoder Position
J54
Drive Encoder Fine Position
J55
Sensorless Mode Position
J56
Maximum Distance Error
J57
Maximum Speed Error
J58
Travel Counter
J59
Output Power
J60
Output Frequency
J61
Output Voltage
J62
Last Travel Maximum Power
J63
Last Travel Maximum Motor Voltage
J64
Last Travel Maximum Current
J65
D.c. Bus Voltage
J66
Internal IO Identifier
J67
Encoder Feedback Interface Identifier
J68
Menu Access Status
J69
Enable Conditions
J70
Drive Event Flags
J71
Monitored Temperature 1
J72
Monitored Temperature 2
J73
Monitored Temperature 3
J74
Monitor Temperature Select 1
J75
Monitor Temperature Select2
J76
Monitor Temperature Select 3
J77
Inverter Temperature
Percentage Of DC Link Thermal Trip
J78
Level
Percentage Of Drive Thermal Trip
J79
Level
J80
Date
J81
Time
J82
Day Of Week
J83
Date And Time Offset
J84
Energy Meter: MWh
J85
Energy Meter: kWh
J86
Energy Cost Per kWh
J87
Running Cost kWh
J88
Drive Date Code
J89
Serial Number LS
J90
Serial Number MS
J91
Drive Identifier Characters
Drive Identifier Rating And
J92
Configuration
J93
Extra Identifier Characters 1
J94
Extra Identifier Characters 2
J95
Extra Identifier Character 3
J96
Drive Derivative
J97
A3 Velocity Threshold Status Output
RW
Read / Write
RO
Character
Chr
Bin
parameter
Num
Number parameter
DE
FI
Filtered
US
334
Electrical
Getting
User Menu A Commissioning
installation
started
Range( )
Open-Loop
-2147483648 to 2147483647
±VM_POWER kW
±VM_SPEED_
FREQ_REF Hz
±VM_AC_VOLTAGE V
0.000 to 32.767 kW
0 to 32767 V
0.000 to 32.767 A
±VM_DC_VOLTAGE V
0 to 255
0 to 255
Menu 0 (0), All Menus (1)
000000000000 to 111111111111
00 to 11
±250 °C
±250 °C
±250 °C
0 to 1999
0 to 1999
0 to 1999
±250 °C
0 to 100 %
0 to 100 %
00-00-00 to 31-12-99
00:00:00 to 23:59:59
Sunday (0), Monday (1), Tuesday (2),
Wednesday (3), Thursday (4), Friday (5),
Saturday (6)
±24.00 Hours
±999.9 MWh
±99.99 kWh
0.0 to 600.0
±32000
0 to 65535
000000000 to 999999999
0 to 999999999
1160982576 to 2147483647
00000000 to 99999999
-2147483648 to 2147483647
-2147483648 to 2147483647
-2147483648 to 2147483647
0 to 255
Read-only
Bit
Bit parameter
Binary parameter
IP
IP address
Destination
ND
No default value
User save
PS
Power-down save
Advanced
Parameters
RFC-A
RFC-S
Open-Loop
0 to 65535
0 to 65535
-2147483648 to
2147483647
0 to 10000 mm
0 to 10000 mm/s
±2000.0 Hz
Off (0) or On (1)
Txt
Text string
Mac MAC address
RA
Rating dependent
Diagnostics Optimization CT MODBUS RTU Technical Data
Default( )
RFC-A
RFC-S
RO
Num ND
RO
Num ND
RO
Num ND
RO
Num ND
RO
Num ND
RW Num ND
RO
Num ND
RO
Num ND
RO
Num ND
RO
Num ND
RO
Num ND
RO
Num ND
RO
Num ND
RO
Num ND
RO
Num ND
RO
Txt
RO
Bin
00
RW
Bin
RO
Num ND
RO
Num ND
RO
Num ND
1001
RW Num
1002
RW Num
1
RW Num
RO
Num ND
RO
Num ND
RO
Num ND
RW Date ND
RW Time ND
RO
Txt
0.00 Hours
RW Num
RO
Num ND
RO
Num ND
0.0
RW Num
RO
Num ND
RO
Num ND
RO
Num ND
RO
Num ND
RO
Num ND
RO
Num ND
RO
Num ND
RO
Num ND
RO
Num ND
RO
Num ND
RO
Bit
Date Date parameter
Time Time parameter
Ver
Version number
SMP
NC
Non-copyable
Type
NC PT
PS
NC PT
NC PT
NC PT
NC PT
NC PT
PS
NC PT
FI
NC PT
FI
NC PT
FI
NC PT
NC PT
NC PT
NC PT
FI
NC PT
NC PT
ND
NC PT
PS
ND
NC PT
NC
NC PT
NC PT
NC PT
US
US
US
NC PT
NC PT
NC PT
NC PT
NC PT
ND
NC PT
US
NC PT
PS
NC PT
PS
US
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
NC PT
ND
NC PT
Slot, menu,
parameter
PT
Protected
E300 Design Guide
Issue Number: 1

Advertisement

Table of Contents
loading

Table of Contents