Emerson E300 Series Design Manual page 323

Advanced elevator drive / dedicated elevator variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for E300 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Open-loop mode
Total Output Current (J22)
Torque Producing Current (J24)
Magnetizing Current (J25)
Output Frequency (J60)
Output Voltage (J61)
Output Power (J59)
D.c. Bus Voltage (J65)
T5 T6 Analog Input 1 (F35)
T7 Analog Input 2 (F36)
T8 Analog Input 3 (F37)
H46
Mode
Minimum
Default
Type
Display Format
Coding
Value
0
1
2
3
4
5
6
If Number Of Autoreset Attempts (H46) = 0 then no auto-reset attempts are made. Any other value will cause the drive to automatically reset following
a trip for the number of times programmed after a delay defined by Auto-reset Delay (H47) subject to the minimum reset time allowed for the type of
trip. Note that for some trips the minimum is 10 s. The auto-reset count is only incremented when the trip is the same as the previous trip otherwise it
is reset to 0. When the auto-reset count reaches the programmed value, any further trip of the same value will not cause an auto-reset. If the number
of auto-reset attempts defined by Number Of Autoreset Attempts (H46) has not been reached and there has been no trip for 5 minutes then the auto-
reset count is cleared. Auto reset will not occur after any trips with priority levels 1, 2 or 3 as defined in Trip 0 (L29). When a manual reset occurs the
auto-reset counter is reset to zero.
If Number Of Autoreset Attempts (H46) = 6 the auto-reset counter is held at zero, and so there is no limit on the number of auto-reset attempts.
H47
Mode
Minimum
Default
Type
Display Format
Coding
See Number Of Autoreset Attempts (H46).
E300 Design Guide
Issue Number: 1
Electrical
Getting
User Menu A Commissioning
installation
started
RFC-A or RFC-S modes
Speed Error (J31)
Speed Loop Output (J32)
Total Output Current (J22)
Torque Producing Current (J24)
Magnetizing Current (J25)
Output Frequency (J60)
Output Voltage (J61)
Output Power (J59)
D.C. Bus Voltage (J65)
T5 T6 Analog Input 1 (F35)
T7 Analog Input 2 (F36)
T8 Analog Input 3 (F37)
Number Of Autoreset Attempts
Open-Loop, RFC-A, RFC-S
0
0
8 Bit User Save
Standard
RW, TE
Text
None
1
2
3
4
5
Infinite
Auto-reset Delay
Open-Loop, RFC-A, RFC-S
1.0
1.0
16 Bit User Save
Standard
RW
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Maximum
6
Units
Update Rate
Background read
Decimal Places
0
Maximum
600.0
Units
s
Update Rate
Background read
Decimal Places
1
323