Emerson E300 Series Design Manual page 52

Advanced elevator drive / dedicated elevator variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for E300 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
3.10.2
Standard external EMC filter details
The external EMC filter details for each drive rating are provided in the table below.
Table 3-11 Standard external EMC filter data
Model
200 V
03200050 to 03200106
04200137 to 04200185
05200250
06200330 to 06200440
07200610 to 07200830
400 V
03400025 to 03400100
04400150 to 04400172
05400270 to 05400300
06400350 to 06400470
07400660 to 07401000
575 V
05500030 to 05500069
06500100 to 06500350
07500440 to 07500550
690 V
07600190 to 07600540
The external EMC filters for sizes 3 to 6 can be footprint mounted or bookcase mounted as shown below. The external EMC filters for size 7 is
designed to be mounted above the drive as shown below.
Figure 3-32
Footprint mounting the EMC filter
52
Electrical
Getting
User Menu A Commissioning
installation
started
Figure 3-33
Bookcase mounting the EMC filter
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
CT part number
4200-3230
4200-0272
4200-0312
4200-2300
4200-1132
4200-3480
4200-0252
4200-0402
4200-4800
4200-1132
4200-0122
4200-3690
4200-0672
4200-0672
Figure 3-34
Size 7 to 10 mounting of the EMC filter
Weight
kg
Ib
1.9
4.20
4.0
8.82
5.5
12.13
6.5
14.3
6.9
15.2
2.0
4.40
4.1
9.04
5.5
12.13
6.7
14.8
6.9
15.2
7.0
15.4
7.0
15.4
E300 Design Guide
Issue Number: 1

Advertisement

Table of Contents