Emerson E300 Series Design Manual page 221

Advanced elevator drive / dedicated elevator variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for E300 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Parameter
C01
Drive Encoder Type
Drive Encoder Auto Configuration
C02
Select
Drive Encoder Rotary Pulses Per
C03
Revolution
C04
Drive Encoder Voltage Select
C05
Drive Encoder Termination Select
C06
Drive Encoder Comms Baud Rate
C07
Drive Encoder Rotary Turns Bits
C08
Drive Encoder Comms Bits
C09
Drive Encoder Feedback Filter
Drive Encoder Additional Power Up
C10
Delay
Drive Encoder Position Feedback
C11
Signals
C12
Drive Encoder Feedback Reverse
RFC-A: RFC Feedback Mode
C14
RFC-S: Sensorless Feedback Mode
C17
Sensorless Mode Filter
C18
Position Feedback Initialise
C19
Position Feedback Initialized Indication
C20
Drive Encoder Protocol Detected
C21
Drive Encoder Error Detection Level
C22
Drive Encoder Error Detected
Drive Encoder Source Maximum
C23
Reference
C24
Drive Encoder Calculation Time
C25
Drive Encoder Recovery Time
C26
Drive Encoder Line Delay Time
Drive Encoder Low Speed Update Rate
C27
Active
C28
Encoder Simulation Source
C29
Encoder Simulation Status
C30
Encoder Simulation Sample Period
C31
Encoder Simulation Mode
C32
Encoder Simulation Hardware Divider
Encoder Simulation Hardware Marker
C33
Lock
Encoder Simulation Incremental Mode
C34
Select
Encoder Simulation Output Lines Per
C35
Revolution
C36
Encoder Simulation Numerator
C37
Encoder Simulation Denominator
Encoder Simulation Output Roll-over
C38
Limit
C39
Encoder Simulation SSI Turns Bits
C40
Encoder Simulation SSI Comms Bits
RW
Read / Write
RO
Chr
Character parameter
Bin
Num
Number parameter
DE
FI
Filtered
US
E300 Design Guide
Issue Number: 1
Electrical
Getting
User Menu A Commissioning
installation
started
Range( )
RFC-A
AB (0), FD (1), FR (2), AB Servo (3),
FD Servo (4), FR Servo (5), SC (6),
SC Hiperface (7), EnDat (8), SC EnDat (9),
SSI (10), SC SSI (11), SC Servo (12),
BiSS (13), SC SC (15),
Commutation Only (16)
Disabled (0), Enabled (1)
1 to 100000
5V (0), 8V (1), 15V (2)
100k (0), 200k (1), 300k (2), 400k (3),
500k (4),1M (5), 1.5M (6), 2M (7), 4M (8) Baud
0 to 16
0 to 48
Disabled (0), 1 ms (1), 2 ms (2),
4 ms (3), 8 ms (4), 16 ms (5)
0.0 to 25.0 s
000000 to 111111
Off (0) or On (1)
Feedback (0), Sensorless (1),
Feedback NoMax (2), Sensorless NoMax (3)
4 (0), 8 (1), 16 (2), 32 (3), 64 (4) ms
Off (0) or On (1)
0000000000 to 1111111111
None (0), Hiperface (1), EnDat2.1 (2),
EnDat2.2 (3), BiSS (4)
0000 to 1111
Off (0) or On (1)
0 to 33000
0 to 20 µs
5 to 100 µs
0 to 5000 ns
Off (0) or On (1)
A00 to AB99
None (0), Full (1), No Marker Pulse (2)
0.25 (0), 1 (1), 4 (2), 16 (3) ms
Hardware (0), Lines Per Rev (1),
Ratio (2), SSI (3)
Off (0) or On (1)
Off (0) or On (1)
1 to 16384
1 to 65536
1 to 65536
1 to 65535
0 to 16
2 to 48
Read-only
Bit
Bit parameter
Binary parameter
IP
IP address
Destination
ND
No default value
User save
PS
Power-down save
Advanced
Parameters
RFC-S
RFC-A
AB (0)
1024
0 to 2
1500
0 to 7
Txt
Text string
Mac
MAC address
RA
Rating dependent
Diagnostics Optimization CT MODBUS RTU Technical Data
Default( )
RFC-S
SC EnDat (9)
RW
Txt
Enabled (1)
RW
Txt
2048
RW Num
5V (0)
RW
Txt
1
RW Num
300k (2) Baud
RW
Txt
16
RW Num
0
RW Num
Disabled (0)
RW
Txt
1.5 s
RW Num
RO
Bin
Off (0)
RW
Bit
Feedback (0)
RW
Txt
4 (0) ms
RW
Txt
Off (0)
RW
Bit
0000000000
RO
Bin
RO
Txt
0001
RW
Bin
RO
Bit
3000
RW Num
5 µs
RW Num
30 µs
RW Num
RO
Num ND NC PT US
RO
Bit
A00
RW Num
RO
Txt
0.25 (0) ms
RW
Txt
Hardware (0)
RW
Txt
0
RW Num
Off (0)
RW
Bit
Off (0)
RW
Bit
4096
RW Num
65536
RW Num
65536
RW Num
65535
RW Num
16
RW Num
33
RW Num
Date
Date parameter
Time
Ver
Version number
SMP
NC
Non-copyable
PT
Type
US
US
US
US
US
US
US
US
US
US
ND NC PT
US
US
US
NC
NC PT
ND NC PT
US
ND NC PT
US
US
US
ND NC PT
PT US
ND NC PT
US
US
US
US
US
US
US
US
US
US
US
Time parameter
Slot, menu, parameter
Protected
221

Advertisement

Table of Contents
loading

Table of Contents