Getting Started; Keypad Set-Up Menu - Emerson E300 Series Design Manual

Advanced elevator drive / dedicated elevator variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for E300 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
5

Getting started

Incorrect operation
Adjustment of drive parameters could result in a risk of damage to the product or present a safety hazard. Careful consideration to the
adjustment of drive parameters must be taken. The user should ensure they are familiar with parameter access, navigation and
parameter operation by reading this guide before adjustment to avoid the risk of damage to the product or a potential safety hazard.
WARNING
The E300 Advanced Elevator drive has both a mounted keypad (KI-Elv Keypad RTC) and an alternative remote mount keypad (CI-Elv Remote
Keypad). Each keypad has the same LCD text display.
Figure 5-1 Keypad buttons
The keypad consists of a number of buttons, keys as detailed following which support navigation and editing.
1. Escape button - Used to exit from parameter edit or view mode. In parameter edit mode, if parameter values are edited and the exit button
pressed, the parameter value will be restored to the value it had on entry to edit mode.
2. Start reverse (Auxiliary) button - Not used.
3. Start forward button - Not used.
4. Navigation keys (x4) - Used to navigate through the menu and parameter structure and edit parameter values.
5. Reset button - Used to reset the drive.
6. Enter / Mode button - Used to toggle between parameter edit and view mode.
NOTE
The remote keypad as shown above has an additional status LED present on the keypad which can be used as a status indication for when the drive
status LED is no longer visible.
5.1

Keypad set-up menu

To enter the keypad set-up menu press and hold the escape
memory when exiting from the set-up menu. To exit from the set-up menu press the escape
Table 5-1 Keypad set-up parameters
Keypad.00
Language
Keypad.01
Show units
Keypad.02
Backlight level
Keypad.03
Keypad date (RTC Keypad)
Keypad.04
Keypad time (RTC Keypad)
Keypad.05
Show numerated text values
Keypad.06
Software version
106
Electrical
Getting
User Menu A Commissioning
installation
started
Local keypad
Parameter
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Remote keypad
1
3
4
button from status mode. All the keypad parameters are saved to non-volatile
Classic English (0), English (1)
Off (0), On (1)
0 to 100 %
01.01.10 to 31.12.99
00:00:00 to 23:59:59
Off (0), On (1)
00.00.00.00 to 99.99.99.99
6
Status LED
5
or
or
button.
Range
E300 Design Guide
Issue Number: 1
Type
RW
RW
RW
RO
RO
RW
RO

Advertisement

Table of Contents
loading

Table of Contents