This sets the Direct to floor deceleration distance setpoint in mm for V1 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
G20
Mode
Minimum
Default
Type
Display Format
Coding
This sets the Direct to floor deceleration distance setpoint in mm for V2 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
G21
Mode
Minimum
Default
Type
Display Format
Coding
This sets the Direct to floor deceleration distance setpoint in mm for V3 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
G22
Mode
Minimum
Default
Type
Display Format
Coding
This sets the Direct to floor deceleration distance setpoint in mm for V4 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
G23
Mode
Minimum
Default
Type
Display Format
Coding
This sets the Direct to floor deceleration distance setpoint in mm for V5 when Direct to floor operation is active, Elevator Control Mode (H19) = Direct
To Floor (1), and Direct To Floor Sensor Mode (H09) = Spd IP+User Dist (2).
E300 Design Guide
Issue Number: 1
Electrical
Getting
User Menu A Commissioning
installation
started
V1 Deceleration Distance Setpoint
RFC-A, RFC-S
0
0
16 Bit User Save
Standard
RW, Num, US
V2 Deceleration Distance Setpoint
RFC-A, RFC-S
0
0
16 Bit User Save
Standard
RW, Num, US
V3 Deceleration Distance Setpoint
RFC-A, RFC-S
0
0
16 Bit User Save
Standard
RW, Num, US
V4 Deceleration Distance Setpoint
RFC-A, RFC-S
0
0
16 Bit User Save
Standard
RW, Num, US
V5 Deceleration Distance Setpoint
RFC-A, RFC-S
0
0
16 Bit User Save
Standard
RW, Num, US
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Maximum
10000
Units
mm
Update Rate
Background
Decimal Places
0
Maximum
10000
Units
mm
Update Rate
Background
Decimal Places
0
Maximum
10000
Units
mm
Update Rate
Background
Decimal Places
0
Maximum
10000
Units
mm
Update Rate
Background
Decimal Places
0
Maximum
10000
Units
mm
Update Rate
Background
Decimal Places
0