Emerson E300 Series Design Manual page 388

Advanced elevator drive / dedicated elevator variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for E300 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Mode: Open-Loop, RFC-A, RFC-S
L01
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Default
Type
8 Bit Volatile
Display Format
Standard
Coding
RO, Txt, ND, NC, PT, BU
Value
Text
0
Inhibit
1
Ready
2
Stop
3
Scan
4
Run
5
Supply Loss
6
Deceleration
7
DC Injection
8
Position
9
Trip
10
Active
11
Off
12
Hand
13
Auto
14
Heat
15
Under Voltage
16
Phasing
Drive Status (L01) shows the present status of the drive. The strings from this parameter are also used by the basic keypad to provide the status
display text.
L02
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Default
Type
1 Bit Volatile
Display Format
Standard
Coding
RO, ND, NC, PT
Drive Warning (L02) is set to one if any of the drive warnings is active, and is defined as:
Drive Warning (L02) = Braking Resistor Alarm (L17) OR Motor Overload Alarm (L21) OR Drive Over Temperature Alarm (L22)
L03
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Default
Type
8 Bit Volatile
Display Format
Standard
Coding
RO, ND, NC, PT
This gives an indication of the elevator drive software activity at the point in time when a travel was last travel was interrupted. The value is reset
when a new travel is started. A travel interrupt is actioned when the drive is disabled early or trips during the travel sequencing. See the table below:
388
Electrical
Getting
User Menu A Commissioning
installation
started
Drive Status
Drive Warning
Travel Interrupt Code
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Maximum
16
Units
Update Rate
Background write
Decimal Places
0
Maximum
1
Units
Update Rate
Background write
Decimal Places
0
Maximum
13
Units
Update Rate
Background
Decimal Places
0
E300 Design Guide