Emerson E300 Series Design Manual page 261

Advanced elevator drive / dedicated elevator variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for E300 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
where
I
is the rated torque producing current
TRated
and
Estimated rated shaft power = √3 x Motor Rated Voltage (B03) x Motor Rated Current (B02) x Motor Rated Power Factor (B04) x 0.9
Torque Per Amp (E16) is used in the automatic calculation of the speed controller gains.
RFC-S
Torque Per Amp (E16) is used for automatic speed controller gain set up, and so the correct value for the motor should be entered if this feature is
required.
E17
Mode
Minimum
Default
Type
Display Format
Coding
The Inertia Compensation Total Inertia (E15), Torque Per Amp (E16) and Inertia compensation acceleration (E18) are used to produce a torque feed-
forwards value that should accelerate and decelerate the load at the required rate. This value can be used as a feed-forwards term that is added to
the speed controller output. Inertia Compensation Torque (E17) gives the torque as a percentage of rated torque.
E18
Mode
Minimum
Default
Type
Display Format
Coding
This is the profile generator output acceleration rate, and is set in 100mm/s
E300 Design Guide
Issue Number: 1
Electrical
Getting
User Menu A Commissioning
installation
started
Inertia Compensation Torque
RFC-A, RFC-S
-1000.0
16 Bit Volatile
Standard
RO, ND, NC, PT
Inertia Compensation Acceleration
RFC-A, RFC-S
-1073741.824
32 Bit Volatile
Standard
RO, ND, NC, PT
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Maximum
1000.0
Units
%
Update Rate
4 ms write
Decimal Places
1
Maximum
1073741.823
Units
mm / s² x100
Update Rate
4 ms write
Decimal Places
3
2
units with 3 decimal places where 0.001 = 0.1mm/s
2
.
261