Safety
Product
Mechanical
information
information
installation
A grommet kit is available for size 7 finger guards.
Table 3-1 Grommet kit (size 7)
Drive size
Size 7 - Kit of 8 x single entry grommets
3.4

Installing / removing option modules, keypad

Power down the drive before installing / removing the option module. Failure to do so may result in damage to the product.
CAUTION
Figure 3-4 Installation of a standard option module
NOTE
Option module slots must be used in the following order: slot 3, slot 2 and slot 1
Installing the first option module
Move the option module in direction shown (1).
Align and insert the option module tab in to the slot provided (2), this is highlighted in the detailed view (A).
Press down on the option module until it clicks into place.