Emerson E300 Series Design Manual page 296

Advanced elevator drive / dedicated elevator variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for E300 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
G33
Reference Select Bit 1 Input
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Default
0
Type
1 Bit User Save
Display Format
Standard
Coding
RW
This input bit is used to select the bit 1 speed input when binary or priority speed selection is used, Control Input mode (H11) = Priority 1 Dir, Binary 1
Dir, Priority 2 Dir or Binary 2 Dir (2, 3, 4 or 5).
In priority input mode this selects V2 Speed Reference (G02), but in binary input mode it may be used to select a number of speeds from V2 to V10.
G34
Reference Select Bit 2 Input
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Default
0
Type
1 Bit User Save
Display Format
Standard
Coding
RW
This input bit is used to select the bit 2 speed input when binary or priority speed selection is used, Control Input mode (H11) = Priority 1 Dir, Binary 1
Dir, Priority 2 Dir or Binary 2 Dir (2, 3, 4 or 5).
In priority input mode this selects V3 Speed Reference (G03), but in binary input mode it may be used to select a number of speeds from V4 to V10.
G35
Reference Select Bit 3 Input
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Default
0
Type
1 Bit User Save
Display Format
Standard
Coding
RW
This input bit is used to select the bit 3 speed input when binary or priority speed selection is used, Control Input mode (H11) = Priority 1 Dir, Binary 1
Dir, Priority 2 Dir or Binary 2 Dir (2, 3, 4 or 5).
In priority input mode this selects V4 Speed Reference (G04), but in binary input mode it may be used to select a number of speeds from V8 to V10.
G36
Reference Select Bit 4 Input
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Default
0
Type
1 Bit User Save
Display Format
Standard
Coding
RW
This input bit is used to select the bit 4 speed input when binary or priority speed selection is used, Control Input mode (H11) = Priority 1 Dir, Binary 1
Dir, Priority 2 Dir or Binary 2 Dir (2, 3, 4 or 5).
In priority input mode this selects V5 Speed Reference (G05), but in binary input mode it is not used.
G37
Reference Select Bit 5 Input
Mode
Open-Loop, RFC-A, RFC-S
Minimum
0
Default
0
Type
1 Bit User Save
Display Format
Standard
Coding
RW
This input bit is used to select the bit 5 speed input when binary or priority speed selection is used, Control Input mode (H11) = Priority 1 Dir, Binary 1
Dir, Priority 2 Dir or Binary 2 Dir (2, 3, 4 or 5).
In priority input mode this selects V6 Speed Reference (G06), but in binary input mode it is not used.
296
Electrical
Getting
User Menu A Commissioning
installation
started
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Maximum
1
Units
Update Rate
4 ms
Decimal Places
0
Maximum
1
Units
Update Rate
4 ms
Decimal Places
0
Maximum
1
Units
Update Rate
4 ms
Decimal Places
0
Maximum
1
Units
Update Rate
4 ms
Decimal Places
0
Maximum
1
Units
Update Rate
4 ms
Decimal Places
0
E300 Design Guide
Issue Number: 1