Emerson E300 Series Design Manual page 25

Advanced elevator drive / dedicated elevator variable speed ac drive for induction and permanent magnet motors
Hide thumbs Also See for E300 Series:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Table 2-17 Size 3 emission compliance (200 V drives)
Switching Frequency (kHz)
Motor cable
length (m)
2
3
Using internal filter:
0 – 2
C3
Using internal filter and ferrite ring (2 turns):
0 – 10
C3
10-20
C3
Using external filter:
0 – 20
R (C1)
R (C1)
20 – 100
I (C2)
I (C2)
Table 2-18 Size 3 emission compliance (400 V drives)
Switching Frequency (kHz)
Motor cable
length (m)
2
3
Using internal filter:
0 – 5
C3
Using internal filter and ferrite ring (2 turns):
0 – 10
Using external filter:
0 – 20
R (C1)
R (C1)
20 – 100
I (C2)
I (C2)
Table 2-19 Size 4 emission compliance (200 V drives)
Switching Frequency (kHz)
Motor cable
length (m)
2
3
Using internal filter:
0 – 2
C3
Using internal filter and ferrite ring (2 turns):
0 – 4
C3
Using external filter:
0 – 20
R (C1)
R (C1)
20 – 100
I (C2)
I (C2)
Table 2-20 Size 4 emission compliance (400 V drives)
Switching Frequency (kHz)
Motor cable
length (m)
2
3
Using internal filter:
0 – 4
C3
Using internal filter and ferrite ring (2 turns):
0 – 10
C3
Using external filter:
0 – 20
R (C1)
R (C1)
20 – 100
I (C2)
I (C2)
Table 2-21 Size 5 emission compliance (200 V drives)
Switching Frequency (kHz)
Motor cable
length (m)
2
3
Using internal filter:
0 – 2
C3
Using internal filter and ferrite ring (1 turn – no advantage to 2 turns):
0 – 2
0 – 5
C3
0 – 7
C3
0 – 10
C3
Using external filter:
0 – 20
R (C1)
R (C1)
20 – 100
I (C2)
I (C2)
E300 Design Guide
Issue Number: 1
Electrical
Getting
User Menu A Commissioning
installation
started
4
6
8
12
C4
C4
C4
I (C2) I (C2) I (C2) I (C2) I (C2)
C3
C3
C3
C3
4
6
8
12
C4
C3
C4
I (C2)
I (C2)
I (C2)
I (C2)
C3
C3
C3
C3
4
6
8
12
C4
C4
I (C2)
I (C2)
I (C2)
I (C2)
C3
C3
C3
C3
4
6
8
12
C4
C4
I (C2)
I (C2)
I (C2)
I (C2)
C3
C3
C3
C3
4
6
8
12
C4
C3
C4
C4
C4
C4
I (C2)
I (C2)
I (C2)
I (C2)
C3
C3
C3
C3
Advanced
Diagnostics Optimization CT MODBUS RTU Technical Data
Parameters
Table 2-22 Size 5 emission compliance (400 V drives)
Motor cable
length (m)
16
2
Using internal filter:
0 – 4
0 – 10
C3
No advantage to using ferrite ring
Using external filter:
0 – 20
R (C1)
20 – 100
I (C2)
C3
Table 2-23 Size 5 emission compliance (575 V drives)
Motor cable
length (m)
2
Using internal filter:
16
-
C4
Using internal filter and ferrite ring (2 turns):
0 – 4
0 – 2
Using external filter:
0 – 20
R (C1)
I (C2)
20 – 100
I (C2)
C3
Table 2-24 Size 6 emission compliance (200 V drives)
Motor cable
length (m)
2
16
Using internal filter:
0 – 2
Using internal filter and ferrite ring (1 turn – no advantage to 2 turns):
0 – 2
0 – 5
0 – 7
I (C2)
0 – 10
C3
C3
Using external filter:
0 – 20
R (C1) R (C1) I (C2)
20 – 100
I (C2)
16
Table 2-25 Size 6 emission compliance (400 V drives)
Motor cable
length (m)
2
Using internal filter:
0 – 4
0 – 10
C3
I (C2)
No advantage to using ferrite ring
C3
Using external filter:
0 – 20
R (C1)
20 – 100
I (C2)
16
I (C2)
C3
Switc0hing Frequency (kHz)
3
4
6
8
C3
C4
R (C1)
I (C2)
I (C2)
I (C2)
I (C2)
C3
C3
C3
Switching Frequency (kHz)
3
4
6
8
C3
C3
R (C1)
I (C2)
I (C2)
I (C2)
I (C2)
C3
C3
C3
Switching Frequency (kHz)
3
4
6
8
C3
C4
C3
C3
C3
C4
C4
I (C2)
I (C2)
I (C2)
C3
C3
C3
Switching Frequency (kHz)
3
4
6
8
C3
C4
R (C1)
I (C2)
I (C2)
I (C2)
I (C2)
C3
C3
C3
12
16
C4
I (C2)
I (C2)
C3
C3
12
16
C4
C4
I (C2)
I (C2)
C3
C3
12
16
C4
C4
I (C2)
I (C2)
C3
C3
12
16
C4
I (C2)
I (C2)
C3
C3
25

Advertisement

Table of Contents
loading