Safety
Product
Mechanical
Information
Information
Installation
2

Product Information

2.1

Quantum MP System Description

The Quantum MP drive system consists of:
1)
Base Mentor MP DC drive
2)
Line fuses
3)
Armature fuse (Regenerative models only)
4)
Motor and Braking Resistor contactors
5)
120 Vac digital I/O and power source

Table 2-1 Model to frame size cross reference

Model
QMP45A4(R)
QMP75A4(R)
QMP155A4(R)
QMP210A4(R)
QMP350A4(R)
QMP400A4(R)
QMP550A4(R)
QMP700A4(R)
2.2

Ratings

The power ratings for the 480V configurations is shown in Table 2-2 .
The continuous current ratings given are for a maximum ambient
temperature of 40°C (104°F) and an altitude of 1000m. For operation at
higher temperatures and altitudes de-rating is required.
For further information see Chapter 12 Technical Data on page 147.

Table 2-2 480V drive ratings

AC input
current
Model
Continuous Continuous Overload
A
QMP45A4(R)
40
QMP75A4(R)
67
QMP155A4(R)
139
QMP210A4(R)
188
QMP350A4(R)
313
QMP400A4(R)
360
QMP550A4(R)
492
QMP700A4(R)
626
Maximum continuous input current
The values of maximum continuous input current are given to aid the
selection of cables and fuses. These values are stated for worst-case
condition.
6
Electrical
Getting
Basic
Installation
Started
parameters
Frame size
1A
1B
2A
2B
Typical motor
DC output current
power
@ 400
Vdc
A
A
kW
45
67.5
15
75
112.5
27
155
232.5
56
210
315
75
350
525
125
400
600
150
550
825
200
700
1050
250
Running the
SMARTCARD
Optimization
Motor
Operation
@ 500
Vdc
hp
27
45
90
125
200
250
300
400
www.emersonct.com
Onboard
Advanced
Technical
Diagnostics
PLC
Parameters
Data
Quantum MP User Guide
UL
Information
Issue: A4