DIAGNOSTICS CHART WITH SELECT MONITOR
VDC (DIAGNOSTICS)
14.Diagnostics Chart with Select Monitor
A: COMMUNICATION FOR INITIALIZING IMPOSSIBLE (SELECT MONITOR
COMMUNICATION FAILURE)
DIAGNOSIS:
• Faulty harness connector
TROUBLE SYMPTOM:
• ABS warning light remains on.
WIRING DIAGRAM:
SBF-4 50A
IGNITION
SWITCH
F45
:
L
1 2 3 4
5 6 7
8 9 10 11 12 13 14 15 16
2
4
6
1
3
5
29
30
31
32
33
56 57
58
59 60
61
62 63
SBF-1 100A
DATA LINK
CONNECTOR
B40
:
B62
L
F45
:
L
F87
VDC CONTROL MODULE
B40
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
8
10
11
12
7
9
13
34
35
36
37
38
39
40
64
65
66
67
68
69
70
BATTERY
GENERATOR
:
B100
R
F2
:
R
F2
1 2
3 4
5 6
12 13 14 15 16 17 18 19 20 21 22 23 24
F87
14
16
18
20
15
17
19
41
42
43
44
45
46
47
71
72
73
74
75
76
77
VDC-130
: RHD MODEL
R
: LHD MODEL
L
:
R
7
8 9 10 11
22
24
26
21
23
25
27
48
49
50
51
52
53
54
78
79
80
81
82 83
28
55
VDC00183