A: SPECIFICATIONS
1. HEATER SYSTEM
Item
Heating capacity
Air flow rate
Max air flow rate
Heater core size
(height × length × width)
Type
Blower
motor
Fan type and size
(diameter × width)
GENERAL DESCRIPTION
Specifications
5.0 kW (4,300 kcal/h, 17,062 BTU/
LHD model
h) or more
5.58 kW (4,800 kcal/h, 19,046
RHD model
BTU/h) or more
3
LHD model
300 m
(10,593 cu ft)/h
3
RHD model
300 m
(10,593 cu ft)/h
3
LHD model
500 m
(17,655 cu ft)/h
3
RHD model
480 m
(16,949 cu ft)/h
193.5 × 152 × 35.0 mm
LHD model
(7.62 × 5.98 × 1.378 in)
181.5 × 160 × 27 mm
RHD model
(7.15 × 6.30 × 1.06 in)
LHD model
Magnet motor 230 W or less
RHD model
Magnet motor 220 W or less
Sirocco fan type
LHD model
150 × 75 mm (5.91 × 2.95 in)
Sirocco fan type
RHD model
150 × 75 mm (5.91 × 2.95 in)
• Mode selector switch: HEAT
• Temperature control switch: FULL HOT
• Temperature difference between hot water
and inlet air: 65°C (149°F)
• Hot water flow rate: 360 2 (95.1 US gal,
79.2 Imp gal)/h
Heat mode (FRESH), FULL HOT at 12.5 V
• Temperature control switch: FULL COLD
• Blower fan speed: 4th position
• Mode selector lever: RECIRC
at 12 V