DX100
12.1
工控帮助教小舒QQ:2823408167
12
DX100 Specification

12.1 Specification List

Specification List
Controller Construction
Dimensions
Cooling System
Ambient
Temperature
Relative Humidity
Power Supply
Grounding
Digital I/O
Positioning System
Drive Unit
Acceleration/
Deceleration
Memory Capacity
Small capacity
MA1400, MA1900, VA1400, MH5L, MH6, HP20D, HP20D-6,
425(W) × 1200(H) × 450(D) mm
A-Type
(standard)
Medium and
MH50, MS80, ES165D, ES200D, VS50
425(W) × 1200(H) × 450(D) mm
Large capacity
A-Type
(standard)
12-2
Free-standing, enclosed type
Refer to following
Indirect cooling
0°C to + 45°C (During operation)
-10°C to + 60°C (During transit and
storage)
10% to 90%RH (non-condensing)
3-phase, 200/220 VAC (+10% to -15%)
at 60Hz(±2%)
200 VAC(+10% to -15%) at 50Hz(±2%)
Grounding resistance: 100Ω or less
Exclusive grounding
Specific signal (hardware)
23 inputs and 5 outputs
General signals (standard, max.)
40 inputs and 40 outputs
(Transistor: 32 outputs, Relay: 8 outputs)
By serial communication
(absolute encoder)
SERVOPACK for AC servomotors
Software servo control
200000 steps, 10000 instructions