Auto Backup Set Display - YASKAWA DX100 Instructions Manual

Hide thumbs Also See for DX100:
Table of Contents

Advertisement

DX100

9.3.2.2 AUTO BACKUP SET Display

工控帮助教小舒QQ:2823408167
9
System Backup
9.3
Automatic Backup Function
Settings
Select the following items on the AUTO BACKUP SET display and set
values for the automatic backup.
• RESERVE TIME BACKUP (VALID/INVALID of the cyclic backup)
• BASE TIME
• BACKUP CYCLE
• RETRY CYCLE
• MODE CHANGE BACKUP (VALID/INVALID of the backup when
switching the mode from teach mode to play mode)
• STARTUP AUTO BACKUP (VALID/INVALID of the backup when the
DX 100 is started up)
• SPECIFIC INPUT BACKUP (VALID/INVALID of the backup when
inputting specified signals)
• UNIV.OUT NO. ON ERROR
• DISPLAY AT EMERGENCY
• DURING ALARM OCCURENCE
• STORED FILE SETTING
With the version in which "STORED FILE SETTING" is set-
table, the capacity of a CompactFlash card inserted in the
programming pendant is checked when the setting window
appears. Therefore, a few seconds may be needed to open
the setting window and an error may occur if no Compact-
Flash is inserted.
NOTE
When changing the settings of "STORED FILE SETTING"
or executing "ARRANGE", the files "CMOSBK.BIN" and
"CMOSBK??.BIN" (?? denotes figures) in the Compact-
Flash card are changed in name or deleted. If a certain file
of this type is needed to be saved before changed in name
or deleted, evacuate it into a PC, etc. beforehand.
1. Turn ON the DX100.
– If the auto backup function is already set valid, insert a
CompactFlash.
2. Insert a CompactFlash in the CompactFlash slot on the programming
pendant.
3. Change the security mode to the management mode.