工控帮助教小舒QQ:2823408167
8
System Setup
8.4
ARM Control
WEIGHT (unit: kg)
The weight of the installed load is set.
It is not required to set a correct value, however, it is recommended to set
a value slightly larger than the actual load. (Round up the value with each
fraction between 0.5 to 1 kg.)
X (From S-Axis), Y (From S-Axis) (unit: mm)
The center of gravity position of the installed load is set by the distance in
the direction of X and the direction of Y from S axis center here. It can be
set with a rough value.
The direction of X and Y applies to the robot coordinates. The value is set
by a negative number when the position is in "-" direction.
Load on the S-head (Top View)
S axis center
-Y
U-arm payload
Set the weight and the center of gravity position roughly when the
equipment such as the wire supplying motors is installed on U arm.
A standard value is set when shipping from the factory.
Set the weight in "0" if there is no installing equipment on U arm.
WEIGHT (unit: kg)
The weight of the installing load is set here.
Set a little large value though it does not care by a rough value. (Rase to
a unit in each 0.5 to 1kg)
X (From U-Axis), HEIGHT (From U-Axis) (unit: mm)
The center of gravity position of the installing load is set here. It does not
care by a rough value.
X (From U-Axis) is horizontal distance from U axis rotation center to the
center of gravity position of the load. Set negative number when there is
mass side in the back from U-axis rotation center.
HEIGHT (From U-Axis) is height of the vertical direction from U-axis
rotation center to the center of gravity position of the load.
8-40
-X
+Y
(X position, Y position)
+X