13.2.2 Connection for Tool Shock Sensor (SHOCK)

13.2.2.1 To connect the tool shock sensor directly to the tool shock sensor signal line

Major Axes Control Circuit Board
SRDA-EAXA01
CN512
-3
+24V
-4
SHOCK
工控帮助教小舒QQ:2823408167
13
Description of Units and Circuit Boards
13.2 Major Axes Control Circuit Board (SRDA-EAXA01□)
1. Disconnect the minus SHOCK (-) and plus SHOCK (+) pin terminal
from the DINAMIC connector, the EAXA-CN512 major axes control
circuit board.
2. Connect the minus SHOCK (-) and plus SHOCK (+) pin terminals to
the signal line of the tool shock sensor. Use the following pin terminals
for preparing the end of the signal line.
Pin Terminal Name
Pin Terminal Model
SHOCK-
SHOCK+
Fig. 13-3: Direct Connection to Tool Shock Sensor Signal Line
TMEDN-630809-FA NICHIFU
SHOCK+
TMEDN-630809-MA
NICHIFU
TMEDN-630809-FA
NICHIFU
SHOCK-
TMEDN-630809-MA NICHIFU
13-5
Signal Line Terminal Model
TMEDN-630809-MA
TMEDN-630809-FA
(manufactured by NICHIFU Co.,
Ltd.)
TMEDN-630809-FA
TMEDN-630809-MA
(manufactured by NICHIFU Co.,
Ltd.)
Manipulator cable (signal)
Shock sensor signal cable
Manipulator
Shock sensor
(Option)