Electrical Equipment Specification

8.1

8.1.1 Specification of Limit Switch

8.1.2 Location of Limit Switch

8
Electrical Equipment Specification

8.1 Position of Limit Switch

Position of Limit Switch
1. The interference limit switch at S-, L- and U-axes electrically limit the
operating range of respective axes by adjusting the position of the dog
using the limit switch.
The positions of the mechanical limits (mechanical stoppers) at S-axis
is changeable.
When the limit switch is activated, the power supply to the manipulator
is interrupted, then the manipulator makes an emergency stop as a
result. Refer to section 8.9 "Overrun/Tool Shock Sensor Releasing" in
"DX200 INSTRUCTIONS" for releasing the status of this overrun.
2. The range of S-, L- and U-axes limit switches are set to the maximum
operating range before shipping.
In case of re-adjusting the operating range of each subject
axis, it is also required to change the dog location and limit
NOTE
values in software. Contact your Yaskawa representative if
re-adjustment is required.
The limit switches are optional. See Fig. 8-1 "Location of Limit Switches".
Fig. 8-1: Location of Limit Switches
L-and U-axes interference L.S.
S-axis overrun L.S.
8-1
170904-1CD
L-axis overrun L.S.
HW1482870