• The EIT table contains an invalid ID. The EIT table IDs must contain a valid ID.
The IDs 0x4E, 0x6F, or 0x72 must be present at PID 0x0012
EIT Other Error (DVB only)
The EIT Other Error alarm activates when Event Information Table sections (S0 or S1)
with the same number appear slower than the repetition rate. The range parameter is
independent for each section.
EIT PF Error (DVB only)
The EIT table contains two sub tables: section 0 (EIT-P) and section 1 (EIT-F). If one
sub table is present, then the other table must be present. The EIT PF Error alarm
occurs if section 0 (EIT-P) or section 1 (EIT-F) is missing.
Unreferenced PID Error
A PID is found in each packet and should be referenced in the PMT (Program Map
Tables) or CAT (Conditional Access Table). The alarm activates when a PID that was
not referenced in the PMT or CAT occurs.
Repetition Error
The Repetition Error alarm occurs when one of the following tables falls outside the
maximum repetition rate or range: Running Status Table (RST), Time and Data Table
(TDT).
RST Enable and Repetition
The RST table activates the Repetition Error alarm when the appearance of the
Running Status Table falls outside the maximum repetition rate. Also, the RST table
IDs must contain a valid ID. The IDs 0x70 or 0x72 must be present at PID 0x0013. The
RST Error also occurs when the table ID is not a valid ID.
TDT Enable, TDT Short Range, and TDT Range
The TDT table activates the Repetition Error alarm for the following reasons:
• The TDT Error occurs when the TDT is not detected for the set range.
• The TDT Error occurs when two sections of the Table ID occur faster than the set
Short Range.
• The TDT table contains an invalid ID. The TDT table IDs must contain a valid ID.
The IDs 0x70, 0x72, or 0x73 must be present at PID 0x0014.
MGT Range
The MGT table activates the Repetition Error alarm when the appearance of the Master
Guide Table falls below the minimum repetition rate.
Alarm Descriptions
TVM Series Installation and Operation Handbook
Copyright © 2008, Harris Corporation
203
Need help?
Do you have a question about the TVM9100PKG and is the answer not in the manual?