Alarm Descriptions
Video Alarms Digital Descriptions
The Video Alarms Digital menu contents are listed below.
Format Change
The Format Change alarm is used to indicate that the video format has been changed.
Payload Identifier Mismatch (TVM-VTM-3GB only)
The Payload Identifier Mismatch alarm is used to indicate that the payload received
from the input stream does not match the detected input format such as HD/SD and
frame rate.
Loss of Payload Identifier (TVM-VTM-3GB only)
The Loss of Payload Identifier alarm is used to indicate when the video payload is not
detected in the received data stream for a period in excess of the duration setting.
Digital Gamut
RGB Gamut Upper/Lower
The RGB Upper and Lower alarm occurs when any component of the transcoded RGB
signal falls outside the upper or lower limits for a period in excess of the duration
setting. The Sensitivity can be increased to provide immunity to fast transcoding
spikes.
Luma Gamut Upper/Lower
The Luma Upper and Lower alarms scan the composite encoded signal derived from
the selected digital input. The alarms occur when the luminance video falls outside the
adjustable limits for a period in excess of the duration setting. The Sensitivity can be
increased to provide immunity to fast noise spikes.
Peak Gamut Upper/Lower
The Peak Upper and Lower alarms scan the composite encoded signal derived from the
selected digital input. The alarm occurs when the peak video falls outside the
adjustable limits for a period in excess of the duration setting. The Sensitivity can be
increased to provide immunity to fast noise spikes.
EDH – SD
Per SMPTE RP 165-1994; the EDH-SD alarm occurs when one or more errors are
detected for a period in excess of the duration setting (Standard definition only).
TVM Series Installation and Operation Handbook
191
Copyright © 2008, Harris Corporation