Diagnostics And Interrupt - YASKAWA VIPA System SLIO Manual

Analog signal modules - sm 03x
Hide thumbs Also See for VIPA System SLIO:
Table of Contents

Advertisement

Analog Input
031-1CB30 - AI 2x16Bit 0...10V > Diagnostics and interrupt
SUPR Interference fre-
quency suppression
CHxFN Function number
channel x
0 ... 10V
Meas. range
(funct. no.)
0 ... 10V
Siemens S7 format
(10h)
0 ... 10V
Siemens S5 format
(20h)
CHxUL CHxLL Upper limit
value Lower limit value
channel x
3.17.3

Diagnostics and interrupt

Event
Error in project
engineering/parameterization
Measuring range overflow
196
Byte
Bit 7 ... 0
0
n
Bit 1, 0: Interference frequency suppression channel 0
n
Bit 3, 2: Interference frequency suppression channel 1
n
Bit 7 ... 4: reserved
In the following there are the measuring ranges with function number listed, which were
supported by the analog module. With FFh the corresponding channel is deactivated. The
formulas listed here allow you to transform an evaluated measuring value (digital value)
to a value assigned to the measuring range (analog value) and vice versa.
Voltage
Decimal
(U)
(D)
11.76V
32511
10V
27648
5V
13824
0V
0
-1.76V
-4864
12.5V
20480
10V
16384
5V
8192
0V
0
-2V
-3277
For each channel an upper and a lower limit may be defined. Here only values of the
nominal range may be preset, otherwise you receive a parameterization error. By preset-
ting 7FFFh for the upper respectively 8000h for the lower limit value the corresponding
limit is deactivated. As soon as the measuring value is beyond the limits and the limit
value monitoring is activated, a process interrupt is initialized.
00: deaktiviert
01: 60Hz
10: 50Hz
00: deaktiviert
01: 60Hz
10: 50Hz
Hex
7EFFh
6C00h
3600h
0000h
ED00h
5000h
4000h
2000h
0000h
F333h
Process
interrupt
-
-
Range
Formulas
overrange
nominal range
underrange
overrange
nominal range
underrange
Diagnostics
parameterizable
interrupt
X
X
HB300 | SM-AIO | | en | 17-05