Purpose
Action
1104
[edit]
set ethernet-switching-options redundant-trunk-group group-name group1
set ethernet-switching-options redundant-trunk-group group-name group1 interface ge-0/0/9.0
primary
set ethernet-switching-options redundant-trunk-group group-name group1 interface ge-0/0/10.0
Configure the redundant trunk group
secondary links.
Configure the redundant trunk group
1.
[edit ethernet-switching-options]
user@switch# set redundant-trunk-group group-name group1
Configure the trunk port
2.
secondary link:
[edit ethernet-switching-options]
user@switch# set redundant-trunk-group group-name group1 interface ge-0/0/9.0
primary
user@switch# set redundant-trunk-group group-name group1 interface ge-0/0/10.0
Display the results of the configuration:
user@switch# show
ethernet-switching-options {
redundant-trunk-group {
group-name group1 {
interface ge-0/0/9.0 primary;
interface ge-0/0/10.0;
}
}
}
}
Verify that the redundant trunk group
Verifying That the Redundant Group Has Been Created on page 1104
Verifying That the Redundant Group Has Been Created
Verify that the redundant trunk group
trunk ports are members of the redundant trunk group.
List all redundant trunk groups configured on the switch:
user@switch> show redundant-trunk-group group1
Redundant-trunk-group: group1
Interfaces
: ge-0/0/9.0
: ge-0/0/10.0 (A) , UP
Bandwidth
: 1000 Mbps, 1000 Mbps
Last Time of Flap
: 1970-01-01 00:19:12 UTC (00:00:06 ago), Never
#Flaps
: 1, 0
on Switch 3 and specify the primary and
group1
:
group1
as the primary link and
ge-0/0/9.0
group1
has been created and is operating properly:
has been created on the switch and that
group1
(P) , DOWN
as the
ge-0/0/10