Chassis Member - Dell PowerConnect J-EX4200-24T Software Manual

J series; j-ex series
Table of Contents

Advertisement

Verifying the Member ID, Role, and Neighbor Member Connections of a Virtual Chassis
Member
Purpose
Action
Meaning
Related
Documentation
Junos OS System Basics and Services Command Reference at
http://www.juniper.net/techpubs/software/junos/
You can designate the role that a member performs within a Virtual Chassis configuration
or you can allow the role to be assigned by default. You can designate the member ID
that is assigned to a specific switch by creating a permanent association between the
switch's serial number and a member ID, using a preprovisioned configuration. Or you
can let the member ID be assigned by the master, based on the sequence in which the
member switch is powered on and on which member IDs are currently available.
The role and member ID of the member switch are displayed on the front-panel LCD.
Each member switch can be cabled to one or two other member switches, using either
the dedicated Virtual Chassis ports (VCPs) on the rear panel, an uplink module port that
has been configured as a VCP, or an SFP network port on a J-EX4200-24F switch that
has been configured as a VCP. The members that are cabled together are considered
neighbor members.
To display the role and member ID assignments using the CLI, use the
status
command:
user@SWA-0> show virtual-chassis status
Virtual Chassis ID: 0000.e255.00e0
Member ID
Status
Serial No
0 (FPC 0)
Prsnt
abc123
1 (FPC 1)
Prsnt
def456
2 (FPC 2)
Prsnt
abd231
This output verifies that three J-EX4200 switches have been interconnected as a Virtual
Chassis configuration using their dedicated VCPs . The display shows which of the VCPs
is connected to which neighbor. The first port (
member
1
and the second port of member
slots for J-EX Series switches are the same as the member IDs.
The
Mastership Priority
values indicate that the master and backup members have been
explicitly configured, because they are not using the default value (
Configuring Mastership of the Virtual Chassis (CLI Procedure) on page 790
Configuring a Virtual Chassis (CLI Procedure) on page 781
Chapter 46: Verifying Virtual Chassis Configuration
Mastership
Model
Priority
Role
ex4200-48t
255
Master*
ex4200-24t
255
Backup
ex4200-24t
128
Linecard
) of member
vcp-0
0
(
vcp-1
) is connected to member
show virtual-chassis
Neighbor List
ID, Interface
1 vcp-0
2 vcp-1
2 vcp-0
0 vcp-1
0 vcp-0
1 vcp-1
is connected to
0
2
. The FPC
).
128
807

Advertisement

Table of Contents
loading

Table of Contents