Dell PowerConnect J-EX4200-24T Software Manual page 857

J series; j-ex series
Table of Contents

Advertisement

Table 107: Virtual Chassis Configuration Fields
Field
Function
Member Details
Member ID
Specifies the identifier for the member switch. The master
switch assigns member IDs.
Priority
Specifies the mastership priority to be assigned to the
member.
member switches using the dedicated Virtual Chassis ports (VCPs) on the back of the
switch. You do not have to configure the interface for the dedicated VCPs. If you want
to interconnect member switches that are located in different racks or wiring closets,
interconnect them using uplinks configured as VCP interfaces. See "Setting an Uplink
Module Port as a Virtual Chassis Port (CLI Procedure)" on page 792.
To configure a Virtual Chassis for J-EX Series switches using the J-Web interface:
Select
>
Configure
Virtual Chassis
1.
NOTE: After you make changes to the configuration in this page, you must
commit the changes for them to take effect. To commit all changes to
the active configuration, select Commit Options > Commit. See "Using
the Commit Options to Commit Configuration Changes (J-Web
Procedure)" on page 334 for details about all commit options.
The properties you can configure are displayed.
2.
The first section of the Virtual Chassis Configuration page displays the Virtual Chassis
member configuration. the display includes a list of member switches, their member
IDs, and the mastership priority.
The second section displays the operational status of the Virtual Chassis configuration,
member details, and the dedicated and configured Virtual Chassis ports (VCPs).
Enter information into the page as described in Table 107 on page 785.
3.
Click one:
4.
—To add a member's configuration to the Virtual Chassis configuration, click
Add
.
Add
—To modify an existing member's configuration, click
Edit
Delete
—To delete the configuration of a member, click
To configure an uplink as a VCP, select the member in the Virtual Chassis members
5.
list and select
Action > Select Uplink Port as VCP
To delete an uplink VCP from a member, select the member in the Virtual Chassis
6.
members list and select
.
. Select the port from the list.
Action > Delete Uplink Port as VCP
Your Action
Select an identifier from the list. Select an
ID from
Select a number from
255 being the highest priority (
default).
Chapter 45: Configuring Virtual Chassis
.
Edit
Delete
.
.
0
through
9
.
1
through
255
, with
is the
128
785

Advertisement