Configuring A Virtual Chassis (J-Web Procedure) - Dell PowerConnect J-EX4200-24T Software Manual

J series; j-ex series
Table of Contents

Advertisement

Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS
Related
Documentation

Configuring a Virtual Chassis (J-Web Procedure)

784
NOTE: The properties that you specify for SWA-0 apply to the entire
Virtual Chassis configuration, including all the members interconnected
through VCPs..
Configure SWA-0 with the virtual management Ethernet (VME) interface for
4.
out-of-band management of the Virtual Chassis configuration, if desired.
[edit]
user@SWA-0# set interfaces vme unit 0 family inet address /ip-address/mask/
Configure mastership priority for the master, backup, and other members, if desired:
5.
[edit virtual-chassis]
user@SWA–0# set member 0 mastership-priority 255
user@SWA–0# set member 5 mastership-priority 255
Power on the member switches in sequential order, one by one.
6.
NOTE: If you do not edit the Virtual Chassis configuration file, a
nonprovisioned configuration is generated by default. The mastership priority
value for each member switch is
You can change the role that is performed by the members by modifying the
mastership-priority. See "Configuring Mastership of the Virtual Chassis (CLI
Procedure)" on page 790. We recommend that you specify the same mastership
priority value for the desired master and backup members. We have assigned
the highest possible mastership priority to two members. However, the
member that was powered on first has higher prioritization according to the
master election algorithm. See "Understanding How the Master in a Virtual
Chassis Configuration Is Elected" on page 698. We have allowed the other
members to use the default mastership priority, which qualifies them to
function in the role of linecard.
NOTE: If you want to change the member ID that the master has assigned
to a member switch, use the request virtual-chassis renumber command.
Configuring a Virtual Chassis (J-Web Procedure) on page 784
Configuring Mastership of the Virtual Chassis (CLI Procedure) on page 790
Setting an Uplink Module Port as a Virtual Chassis Port (CLI Procedure) on page 792
Monitoring Virtual Chassis Configuration Status and Statistics on page 809
To take advantage of the scalability features of J-EX4200 switches, you can configure
a Virtual Chassis that includes up to 10 member switches. You can interconnect the
. The master role is selected by default.