MIB Parameters

Table D-2: Private MIB Parameters (Sheet 3 of 18)
Name
winlink1000OduSrvRingMaxAllowedTimeFrom
LastRpm
winlink1000OduSrvRingWTR
winlink1000OduSrvQoSMode
winlink1000OduSrvQoSConfTable
winlink1000OduSrvQoSConfEntry
winlink1000OduSrvQoSConfIndex
winlink1000OduSrvConfVlanQGroups
winlink1000OduSrvConfDiffservQGroups
winlink1000OduSrvConfQueMir
winlink1000OduSrvConfQueWeight
winlink1000OduSrvQoSVlanQGroupsSetStr
winlink1000OduSrvQoSDiffservQGroupsSetStr 1.3.6.1.4.1.4458.1000.1.2.5.4
winlink1000OduSrvQoSMaxRTQuePercent
winlink1000OduEthernetRemainingRate
winlink1000OduEthernetIfTable
winlink1000OduEthernetIfEntry
winlink1000OduEthernetIfIndex
winlink1000OduEthernetIfAddress
winlink1000OduEthernetIfAdminStatus
winlink1000OduEthernetIfOperStatus
winlink1000OduEthernetIfFailAction
winlink1000OduEthernetNumOfPorts
winlink1000OduBridgeBasePortTable
winlink1000OduBridgeBasePortEntry
winlink1000OduBridgeBasePortIndex
winlink1000OduBridgeBaseIfIndex
winlink1000OduBridgeTpMode
winlink1000OduBridgeTpPortTable
winlink1000OduBridgeTpPortEntry
winlink1000OduBridgeTpPortIndex
winlink1000OduBridgeTpPortInFrames
winlink1000OduBridgeTpPortOutFrames
winlink1000OduBridgeTpPortInBytes
winlink1000OduBridgeTpPortOutBytes
winlink1000OduBridgeConfigMode
winlink1000OduAirFreq
WinLink 1000 User Manual
OID
1.3.6.1.4.1.4458.1000.1.2.4.5
1.3.6.1.4.1.4458.1000.1.2.4.6
1.3.6.1.4.1.4458.1000.1.2.5.1
1.3.6.1.4.1.4458.1000.1.2.5.2.1.1
1.3.6.1.4.1.4458.1000.1.2.5.2.1.2
1.3.6.1.4.1.4458.1000.1.2.5.2.1.3
1.3.6.1.4.1.4458.1000.1.2.5.2.1.4
1.3.6.1.4.1.4458.1000.1.2.5.2.1.5
1.3.6.1.4.1.4458.1000.1.2.5.3
1.3.6.1.4.1.4458.1000.1.2.5.5
1.3.6.1.4.1.4458.1000.1.3.1
1.3.6.1.4.1.4458.1000.1.3.2.1.1
1.3.6.1.4.1.4458.1000.1.3.2.1.5
1.3.6.1.4.1.4458.1000.1.3.2.1.6
1.3.6.1.4.1.4458.1000.1.3.2.1.7
1.3.6.1.4.1.4458.1000.1.3.2.1.8
1.3.6.1.4.1.4458.1000.1.3.3
1.3.6.1.4.1.4458.1000.1.4.4.101
1.3.6.1.4.1.4458.1000.1.4.4.3.1.3
1.3.6.1.4.1.4458.1000.1.4.4.3.1.4
1.3.6.1.4.1.4458.1000.1.4.4.3.1.10
1
1.3.6.1.4.1.4458.1000.1.4.4.3.1.10
2
1.3.6.1.4.1.4458.1000.1.4.4.102
1.3.6.1.4.1.4458.1000.1.5.1
Release 1.9.40
Type
Description
Integer
RW Defines the minimal time (in ms) required for
determination of ring failure.
Integer
RW Defines the minimal time (in ms) required for ring
recovery.
Integer
RW Mode of QoS feature.
N/A QoS configuration table.
N/A QoS configuration table.
winlink1000OduSrvQoSConfIndex }
Integer
RO
Index of QoS Configuration.
Integer
RO
Frames classification according to VLAN Priority
IDs.
Integer
RO
Frames classification according to Diffserv.
Integer
RW Desired Private MIR.
Integer
RW QoS queueu's weights in percent.
DisplayString
RW Frames classification according to VLAN IDs string
for set.
DisplayString
RW Frames classification according to Diffserv IDs
string for set.
Integer
RO
Maximal percent for RT & NRT queues.
Integer
RO
Current Ethernet bandwidth in bps.
N/A ODU Ethernet Interface table.
N/A ODU Ethernet Interface table entry. INDEX {
winlink1000OduEthernetIfIndex }
Integer
RO
ODU Ethernet Interface Index.
DisplayString
RO
ODU MAC address.
Integer
RW Required state of the interface.
Integer
RO
Current operational state of the interface.
Integer
RW Failure action of the interface.
Integer
RO
Number of ODU network interfaces.
N/A ODU Bridge Ports table.
N/A ODU Bridge Ports table entry. INDEX {
winlink1000OduBridgeBasePortIndex }
RO
ODU Bridge Port Number.
RO
IfIndex corresponding to ODU Bridge port.
Integer
RW ODU bridge mode.
reset. Valid values: hubMode (0) bridgeMode (1).
N/A ODU Transparent Bridge Ports table.
N/A ODU Transparent Bridge Ports table entry.
INDEX { winlink1000OduBridgeTpPortIndex }
RO
ODU Transparent Bridge Port Number.
Counter
RO
Number of frames received by this port.
Counter
RO
Number of frames transmitted by this port.
Counter
RO
Number of bytes received by this port.
Counter
RO
Number of bytes transmitted by this port.
Integer
RO
ODU bridge configuration mode
Integer
RW Installation Center Frequency. Valid values are
product dependent. A change is effective after link
re-synchronization.
Appendix D
INDEX {
A change is effective after
D-8