Local Line Loopback; Remote Reverse Loopback; Remote Line Loopback; Figure 9-7 Local Linel - Radwin WinLink 1000 User Manual

Broadband wireless
Hide thumbs Also See for WinLink 1000:
Table of Contents

Advertisement

Local Line Loopback

Local Line Loopback
A Local line loopback can be set to test the local E1/T1 port and its connection to local side
user equipment. In this mode, data coming from the local user equipment is looped back to
it. This loopback is initiated from a managing computer connected to the local unit.
Figure 9-7: Local Line Loopback

Remote Reverse Loopback

A remote reverse loopback can be set to test connection between the local and remote units
and between the local E1/T1 port and its connection to the local user equipment. In this
mode, data coming from the local user equipment is looped back at the remote side. This
loopback is initiated from a managing computer connected to the local unit.
Figure 9-8: Remote Reverse Loopback

Remote Line Loopback

The remote unit can be set to a line loopback to test the remote E1/T1 port and its connec-
tion to the remote side user equipment. In this mode, data coming from the remote user
equipment is looped back to it locally. This loopback is initiated by the managing computer
connected to the local unit.
WinLink 1000 User Manual
Release 1.9.40
Chapter 9
9-6