Changing the Factory
Why this is Needed
All ODUs supplied by RADWIN come with pre-configured with a factory default product-
dependent band according to the ODU part number.
For ODUs supporting Multi-band, it may be changed using the procedure in this chapter. The
procedure is generic, applying to all ODUs with the Multi-band feature.
Caution
Required Equipment
The minimal equipment required to change an ODU default band is:
•
Laptop computer (managing computer) satisfying the requirements of
•
An installed copy of the RADWIN Manager
•
A PoE device
•
A crossed Ethernet LAN cable
•
An IDU-ODU cable
The procedure
The following procedure is generic to all relevant RADWIN radio products.
What you see on your running RADWIN Manager may differ in some details
from the screen captures used to illustrate this chapter.
Note
To change the factory default band:
1. Using the IDU-ODU cable, connect the PoE device to the ODU, ensuring that the
cable is plugged into the PoE port marked P-LAN-OUT.
WinLink 1000 User Manual
•
If for some reason the default band needs to be changed, it should
be done before link installation.
•
Use of an incorrect band may be in violation of local regulations.