Radwin Manager Traps - Radwin WinLink 1000 User Manual

Broadband wireless
Hide thumbs Also See for WinLink 1000:
Table of Contents

Advertisement

RADWIN Manager Traps

Click the
button and in the Select File dialog box indicate in which folder and under what
name the Events Log file is to be saved, and click OK.
To store the Events Log, first define the IP address, subnet mask, default
gateway and trap destination address of the managing computer (see
page 8-7
Note
RADWIN Manager Traps
The RADWIN Manager application issues traps to indicate various events, displayed in the
Events Log.
Table 9-5: RADWIN Manager Trap Messages
Trap Message
Cannot bind to trap service port. Port 162 already in use by
ProcessName (pid: ProcessId)
Device unreachable!
Connected to <site_name>
<site_name> Site will be reset.
Restore Factory Default Settings in process on Site <site_name>
Factory Settings: The process was not finished due to connection
issues.
Reset: The process was not finished due to connection issues.
Cannot Write to Monitor file. There is not enough space on the disk.
Windows Error: <error_ID>. Cannot Write to Monitor file.
TDM Counters were cleared for both sides
Identical IP addresses at <local_site_name> and
<remote_site_name>
The Product is not identified at the <local_site_name> site.
The Product is not identified at the <remote_site_name> site.
The Product is not identified at both sites.
Product Not Identified!
The Manager identified a newer ODU release at the
<remote_site_name> site.
The Manager identified a newer ODU release at both sites.
The Manager identified a newer ODU release at the
<local_site_name> site.
WinLink 1000 User Manual
for details).
Release 1.9.40
Severity
Remarks
Warning
RADWIN Manager will not catch any traps from the
ODU, some other application has grabbed this
port. For further detail see
Error
Check connectivity to ODU
Information
Information
Information
Warning
Factory setting failed due to connectivity problem
to ODU
Warning
Factory setting failed due to connectivity problem
to target - ODU will not be reset
Warning
Free some space on disk on the managing
computer and retry
Warning
Operating System error on the managing computer
Information
Warning
Set up a different IP to each site
Warning
RADWIN Manager is incompatible with the ODU
software version
Warning
Warning
Warning
Warning
ODU release is newer than RADWIN Manager
release.
Wizards are not available. RADWIN Manager will
be used just for monitoring. Upgrade the RADWIN
Manager. (You will get this message as a pop up)
Warning
Warning
Chapter 9
this web
site.
9-15

Advertisement

Table of Contents
loading