Community String

on each of the IDUs and ODUs in the link. Both agents communicate with each other over the
air using a proprietary protocol.
Each ODU has a single MAC address and a single IP address.
Note
To control and configure the device using the MIB, you should adhere to the following rules:
The connection for control and configuration is to the local site, over any SNMP/UDP/
IP network.
All Parameters should be consistent between both of the ODUs. Note that inconsis-
tency of air parameters can break the air connection. To correct air parameters incon-
sistency you must reconfigure each of the ODUs.
Common practice is to configure the remote site first and then to configure the local
site.
For some of the configuration parameters additional action must be taken before the
new value is loaded. Please refer to the operation in the parameters description.
Some of the MIB parameters values are product dependent. It is strongly recommend
using the RADWIN Manager Application for changing these values. Setting wrong val-
ues may cause indeterminate results.
Community String
To control a link, all SNMP requests should go to the local site IP address.
See
Table 4-4
for default Community strings.

Private MIB Structure

The sections in the private RADWIN MIB and its location in the MIB tree are shown in
Figure D-1
below:
WinLink 1000 User Manual
Release 1.9.40
Appendix D
D-2