Protection against Lightning
outdoor unit, mast, lead-in wire and discharge unit. It also lays down the size of
grounding conductors and connection requirements for grounding electrodes.
The WinLink 1000 ODU must be grounded to a Protective Earth as described in
Chapter 18
•
The earth lug on the IDU-C should be connected to the protective earth at all times,
by a wire with a diameter of 18 AWG or wider. Rack-mounted equipment should be
mounted only in earthed racks and cabinets.
Further, you should -
•
Always make the ground connection first and disconnect it last
•
Never connect telecommunication cables to ungrounded equipment
•
Ensure that all other cables are disconnected before disconnecting the ground
More detailed guidelines are supplied in
Protection against Lightning
The use of lightning protection is dependent on regulatory and end user requirements. All of
RADWIN outdoor units are designed with surge limiting circuits to minimize the risk of dam-
age due to lightning strikes. RADWIN recommends the use of additional surge arrestor
devices to protect the equipment from nearby lightning strikes.
See
Chapter 18
for detailed installation instructions of lightning protection devices.
General
•
It is recommended that installation of the outdoor unit be contracted to a professional
installer.
•
Before working on equipment connected to power lines or telecommunication lines,
you should remove jewelry or any other metallic object that may come into contact
with energized parts.
•
Use extreme care when installing antennas near power lines.
•
Use extreme care when working at heights.
•
When using an AC power source for WinLink 1000 always use the AC power adapter
supplied by RADWIN.
•
Use the right tools. In addition to standard tools required for any kind of ODU or
antenna installation, WinLink 1000 requires additional specific tools detailed on
page 3-6
below.
Package Contents
The WinLink 1000 packages include the following items:
ODU Package Contents
The ODU package contains:
•
One ODU - see
•
An ODU mounting kit - see
•
A CD containing -
WinLink 1000 User Manual
and in accordance with the Local Electrical Regulations.
Chapter
Figure 3-2
and
Figure 3-3
Figure 3-1
Release 1.9.40
18.
below for front and rear view
below
Chapter 3
3-2