Mounting the IDU-C

IDU-R Installation

Figure 3-12: IDU-R Rear Panel
Installation of an IDU-R unit differs from other IDU models in one respect: At the rear of the
IDU-R (see
Figure
3-12) there are two jacks labeled "Trunks". For each IDU-R, the E1 cable
from outside should be plugged into one of the trunks, and the E1 cable to the other station
should be plugged into the second trunk, as in the left hand side of
Apart from the above difference, the link installation including the remaining part of the IDU
installation and connection to the ODU proceeds as described as above.
Mounting the IDU-C
IDU-Cs are all rack mountable, as shown in
rack mounted IDU-C is shown in the figure below.
Figure 3-13: IDU-C front panel
Further description of the keyed items in
Table 3-1: Components of an IDU-C front panel
Key
Label
A
Indicator LEDs
B
ODU Port
C
LAN RJ45Ports
D
LAN SFP Port
E
Alarm Ports
F
Label indent
WinLink 1000 User Manual
Figure
3-13. A front panel keyed schematic of a
Figure 3-13
is shown in
Remarks
See
Figure
3-14.
RJ-45 connector, see
Table
B-1.
Ethernet, RJ-45 connector, see
See
Appendix
C.
Standard DB25 female connector, see
Place for adhesive identification labels.
Release 1.9.40
Figure
1-12.
Table 3-1
below:
Table
B-3.
Table
B-7.
Chapter 3
3-10