Using More than One HSS Unit

Using More than One HSS Unit
In a large collocation site, several HSS units may be cascaded (daisy-chained) subject to the
following conditions:

Condition 1: Cabling Sequence

1. Up to nine ODUs may be connected to the first HSS unit using HSS ports SYNC 1, SYNC 2,
SYNC 3,... up to SYNC 9 in order without leaving empty ports.
2. The next available SYNC port of the first HSS unit should be connected to SYNC 10
of the second HSS unit as shown in
available port on the first HSS unit is SYNC 6.
3. The second HSS unit may be filled out with up to nine more ODUs in reverse
order. That is, connect SYNC 9, SYNC 8, SYNC 7... as shown in
Figure 10-7: Cascading two HSS units
4. To add a a further HSS unit: Connect the next available SYNC port from the
second HSS unit in descending order (SYNC 5 in
third HSS unit.
5. ODUs are connected to the third HSS unit from SYNC 2 as shown in
in ascending order: